SEQUENTIAL VIEWING OF ABDOMINAL CT IMAGES AT VARYING RATES

被引:19
作者
GUR, D
GOOD, WF
OLIVER, JH
THAETE, FL
BARON, RL
FEDERLE, MP
CAMPBELL, WL
ROSENTHAL, MS
机构
[1] Department of Radiology, University of Pittsburgh, A449 Scaife Hall, Pittsburgh, PA 15261-0001
关键词
COMPUTED TOMOGRAPHY (CT); IMAGE DISPLAY AND RECORDING; DIAGNOSTIC RADIOLOGY; OBSERVER PERFORMANCE; IMAGES; INTERPRETATION; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC);
D O I
10.1148/radiology.191.1.8134556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate radiologists' ability to detect abdominal masses during sequential viewing of series of computed tomographic (CT) scans at varying rates. MATERIAL AND METHODS: Receiver operating characteristic (ROC) analysis was used to assess the ability of five experienced radiologists to determine the presence or absence of subtle abdominal masses in 29 cases (15 positive, 14 negative) while viewing CT scans sequentially at different rates (0.5, 1, 2, 4, 7, and 21 images per second) and also at reader-selectable rates. RESULTS: Even at extremely fast viewing rates (21 images per second), radiologists performed significantly better (P < .05) than would be expected by chance alone (average area A(z) under the ROC curve = 0.73 vs 0.5). As the viewing rate decreased, their performance increased. The reader-selectable mode was better than any fixed-rate cine mode (average A(z) = 0.93). CONCLUSION. Fixed-rate sequential viewing of CT images for the primary diagnosis of subtle abdominal masses should be restricted to no more than one or two images per second, but the reader-selectable viewing mode is preferable to any fixed-rate cine mode.
引用
收藏
页码:119 / 122
页数:4
相关论文
共 8 条
  • [1] CARBONI NL, 1989, P SOC PHOTO-OPT INS, V1091, P252
  • [2] SPATIAL COMPREHENSION AND COMPARISON PROCESSES IN VERIFICATION TASKS
    GLUSHKO, RJ
    COOPER, LA
    [J]. COGNITIVE PSYCHOLOGY, 1978, 10 (04) : 391 - 421
  • [3] GUR D, 1992, P SOC PHOTO-OPT INS, V1653, P159, DOI 10.1117/12.59495
  • [4] INTERPRETING CHEST RADIOGRAPHS WITHOUT VISUAL SEARCH
    KUNDEL, HL
    NODINE, CF
    [J]. RADIOLOGY, 1975, 116 (03) : 527 - 532
  • [5] CONCEPTUAL MASKING - HOW ONE PICTURE CAPTURES ATTENTION FROM ANOTHER PICTURE
    LOFTUS, GR
    HANNA, AM
    LESTER, L
    [J]. COGNITIVE PSYCHOLOGY, 1988, 20 (02) : 237 - 282
  • [6] Metz CE, 1990, 1990 JOINT STAT M AM
  • [7] PAGE EB, 1963, J AM STAT ASSOC, V59, P906
  • [8] PRIMARY CT DIAGNOSIS OF ABDOMINAL MASSES IN A PACS ENVIRONMENT
    STRAUB, WH
    GUR, D
    GOOD, WF
    CAMPBELL, WL
    DAVIS, PL
    HECHT, ST
    SKOLNICK, ML
    THAETE, FL
    ROSENTHAL, MS
    SASHIN, D
    [J]. RADIOLOGY, 1991, 178 (03) : 739 - 743