POTENTIAL OF THE CONTINUOUS ADDITION OF REAGENT TECHNIQUE FOR CHEMILUMINESCENT REACTION-RATE DETERMINATIONS

被引:5
作者
CEPAS, J [1 ]
SILVA, M [1 ]
PEREZBENDITO, D [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
CHEMILUMINESCENCE; CONTINUOUS ADDITION; COPPER; REACTION-RATE DETERMINATIONS;
D O I
10.1016/0003-2670(94)80069-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemiluminescent (CL) reaction between luminol and hydrogen peroxide in the presence of copper(II) was used to assess the potential of the continuous addition of reagent (CAR) technique for CL determinations. This approach allows this type of reaction to be studied in terms of reaction rate, so maximum reaction-rate measurements can be compared with classical peak height measurements. The reaction-rate method provided better analytical features in the CL determination of copper(II): dynamic range, 1-700 ng ml(-1); precision (R.S.D.), ca. 3%; sample throughput, 48 samples h(-1). In addition, the CAR technique facilitates thorough, reproducible mixing of sample and reagents, in addition to recording the whole CL response curve and altering the rate of the CL process, which can be monitored with a straightforward data acquisition system.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 25 条
[1]   DETERMINATION OF NAPHTHOLS BY FLOW-INJECTION CHEMI-LUMINESCENCE [J].
ALTAMRAH, SA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1987, 202 :247-250
[2]   CHEMILUMINESCENCE DETERMINATION OF IRON(II) AND TITANIUM(III) BY FLOW-INJECTION ANALYSIS BASED ON REACTIONS WITH AND WITHOUT LUMINOL [J].
ALWARTHAN, AA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1987, 196 :135-140
[3]   AUTOMATED KINETIC SPECTROFLUOROMETRIC METHOD FOR THE DETERMINATION OF MORPHINE IN URINE [J].
CEPAS, J ;
SILVA, M ;
PEREZBENDITO, D .
ANALYST, 1993, 118 (07) :923-927
[4]   MICELLAR-ENHANCED AQUEOUS PEROXYOXALATE CHEMILUMINESCENCE [J].
DAN, N ;
LAU, ML ;
GRAYESKI, ML .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1766-1771
[5]  
DELUMYEA RG, 1974, THESIS WAYNE STATE U
[6]   DETERMINATION OF HYPOCHLORITE IN WATERS BY STOPPED-FLOW CHEMI-LUMINESCENCE SPECTROMETRY [J].
GONZALEZROBLEDO, D ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :123-128
[7]   PERFORMANCE OF THE STOPPED-FLOW TECHNIQUE IN CHEMI-LUMINESCENCE SPECTROMETRY BASED ON DIRECT RATE MEASUREMENTS [J].
GONZALEZROBLEDO, D ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1989, 217 (02) :239-247
[8]  
GRAYESKI ML, 1987, ANAL CHEM, V59, pA1243
[9]   KINETIC-STUDY OF BACKGROUND EMISSION FROM PEROXYOXALATE CHEMILUMINESCENCE REACTION AND APPLICATION TO THE IMPROVEMENT OF DETECTION LIMITS IN LIQUID-CHROMATOGRAPHY [J].
HANAOKA, N ;
TANAKA, H ;
NAKAMOTO, A ;
TAKADA, M .
ANALYTICAL CHEMISTRY, 1991, 63 (23) :2680-2685
[10]   IMMOBILIZED LUMINOL CHEMI-LUMINESCENCE REAGENT SYSTEM FOR HYDROGEN-PEROXIDE DETERMINATIONS IN FLOWING STREAMS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :834-837