DESCENDING AORTIC BLOOD-FLOW VELOCITY AS A NONINVASIVE MEASURE OF CARDIAC-OUTPUT IN CHILDREN

被引:17
作者
SEEAR, M
WEBBER, S
LEBLANC, J
机构
[1] CHILDRENS HOSP,DEPT INTENS CARE,VANCOUVER,BC,CANADA
[2] CHILDRENS HOSP,DEPT CARDIOL,VANCOUVER,BC,CANADA
[3] CHILDRENS HOSP,DEPT SURG,VANCOUVER,BC,CANADA
关键词
CARDIAC OUTPUT; CHILDREN; AORTIC BLOOD VELOCITY; ESOPHAGEAL DOPPLER;
D O I
10.1007/BF00800672
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In previous work, we postulated that mean aortic flow velocity (MAFV) might be a direct measure of cardiac index. To investigate the assumptions inherent in this relation, we measured body surface area, aortic cross-sectional area (two-dimensional ultrasonography) and MAFV (Doppler ultrasonography) in 70 normal children. For a direct check of the relation, we simultaneously measured cardiac index (Fick technique) and MAFV (Doppler ultrasonography) in 25 children after cardiac surgery. In the normal group, we found that body surface area was directly proportional to aortic cross-sectional area (R 0.94), and MAFV at rest was the same in the ascending and descending aorta (t test, p < 0.05). In the intensive care patients, MAFV in the descending aorta was directly proportional to cardiac index over a wide clinical range [MAFV (cm/s) = CI (L/min/m2) . 7.7 - 1.2]. The assumptions made when deriving the relation between MAFV and cardiac index appear to be valid whether measured in the ascending or descending aorta. However, the scatter of results limits its clinical value. Mean aortic flow velocity is probably of greater use as a trend indicator and has the potential for continuous display using an esophageal Doppler probe when measured in the descending aorta.
引用
收藏
页码:178 / 183
页数:6
相关论文
共 28 条
[1]  
DAILY E, 1989, TECHNIQUES BEDSIDE H, P182
[2]  
DISTANTE A, 1980, J NUCL MED ALLIED S, V24, P171
[3]   COMPARISON OF PULSED DOPPLER AND THERMODILUTION METHODS FOR MEASURING CARDIAC-OUTPUT IN CRITICALLY ILL PATIENTS [J].
DONOVAN, KD ;
DOBB, GJ ;
NEWMAN, MA ;
HOCKINGS, BES ;
IRELAND, M .
CRITICAL CARE MEDICINE, 1987, 15 (09) :853-857
[4]   CLINICAL-EVALUATION COMPARED TO PULMONARY-ARTERY CATHETERIZATION IN THE HEMODYNAMIC ASSESSMENT OF CRITICALLY ILL PATIENTS [J].
EISENBERG, PR ;
JAFFE, AS ;
SCHUSTER, DP .
CRITICAL CARE MEDICINE, 1984, 12 (07) :549-553
[5]  
ELDRIDGE MW, 1985, J ULTRAS MED, V4, P453
[6]  
GARDIN J, 1989, AM J CARDIOL, V14, P935
[7]  
GEORGE RJD, 1985, BRIT J HOSP MED, V34, P89
[8]  
GOLDBERG S, 1983, CIRCULATION, V68, pA260
[9]  
HAITES NE, 1985, BRIT HEART J, V53, P123
[10]   GEOMETRIC METHOD FOR MEASURING BODY-SURFACE AREA - HEIGHT-WEIGHT FORMULA VALIDATED IN INFANTS, CHILDREN, AND ADULTS [J].
HAYCOCK, GB ;
SCHWARTZ, GJ ;
WISOTSKY, DH .
JOURNAL OF PEDIATRICS, 1978, 93 (01) :62-66