ACCURACY ANALYSIS IN FLOW CALORIMETRY

被引:6
作者
GRINI, PG [1 ]
OWREN, GA [1 ]
MAEHLUM, HS [1 ]
机构
[1] SINTEF,REFRIGERAT ENGN,N-7034 TRONDHEIM,NORWAY
关键词
ACCURACY; CALORIMETRY; ENTHALPY; FLOW CALORIMETRY; NOVEL;
D O I
10.1016/0040-6031(94)02165-K
中图分类号
O414.1 [热力学];
学科分类号
摘要
The accuracy claimed for calorimetric measurements should be given at a certain confidence level. This paper describes how the standard uncertainty of isobaric enthalpy increment measurements from a new cryogenic flow calorimeter is derived. The new calorimeter has several features that reduce the heat leakage better than previous designs. The temperature and pressure ranges covered by-the calorimeter are 133-335 K and 0.17-14 MPa. The enthalpy increment measurements have an average standard uncertainty of 0.10 kJ kg(-1) or 0.25% of the enthalpy increment.