ON THE CORRECTION FOR RADIOACTIVE DECAY IN PHARMACOKINETIC MODELING

被引:17
作者
WILLIAMS, LE
ODOMMARYON, TL
LIU, A
CHAI, A
RAUBITSCHEK, AA
WONG, JYC
DARGENIO, DZ
机构
[1] CITY HOPE NATL MED CTR,DIV BIOSTAT,DUARTE,CA 91010
[2] UNIV CALIF LOS ANGELES,MED CTR,DEPT RADIOL SCI,LOS ANGELES,CA 90024
[3] CITY HOPE NATL MED CTR,DIV RADIAT ONCOL,DUARTE,CA 91010
[4] UNIV SO CALIF,LOS ANGELES,CA 90089
关键词
MODELING; RADIO DECAY; NONLINEAR; MAB;
D O I
10.1118/1.597421
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The question of how to include radioactive decay during biological modeling with first-order differential equations was considered. Modeling may involve either experimental data y(t) or decay-corrected data z(t) [=exp(lambda t)y(t) where lambda is the decay constant] for each compartment. It is sometimes assumed that the latter are solutions to corresponding purely pharmacokinetic models (no decay). We primarily compared the two analyses in the case where the model did not require simultaneous consideration of both labeled and unlabeled material. A general theorem was found which limits the use of decay-corrected data to pharmacokinetic models containing Linear, homogeneous differential equations. By way of verification, an example of this model type was analyzed for a chimeric monoclonal antibody biodistribution in man. Even in this case, statistically significant differences between the two solutions showed that one may find different model parameters depending upon which data set (y or z) was analyzed. For other mathematical forms, the analyst must include the physical decay in all relevant compartments. By analyzing an open, quadratic model, effects of not including decay were seen to be maximized if the biological rate constant was greater than or equal to lambda, the physical decay constant. Finally, using monoclonal antibody-antigen reactions, similar discrepancies between the z functions and the pharmacokinetic variables were demonstrated. This result was found to persist even if competitive molecules were included. We conclude that decay-corrected data may be shown, but should not be entered into-the modeling equations unless the latter are of the linear, homogeneous form.
引用
收藏
页码:1619 / 1626
页数:8
相关论文
共 24 条
[1]
MODELS FOR INVIVO KINETIC INTERACTIONS OF DOPAMINE D2-NEURORECEPTORS AND 3-(2'-[F-18]FLUOROETHYL)SPIPERONE EXAMINED WITH POSITRON EMISSION TOMOGRAPHY [J].
BAHN, MM ;
HUANG, SC ;
HAWKINS, RA ;
SATYAMURTHY, N ;
HOFFMAN, JM ;
BARRIO, JR ;
MAZZIOTTA, JC ;
PHELPS, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (06) :840-849
[2]
BEATTY BG, 1989, CANCER RES, V49, P1587
[3]
APPLICATION OF MULTICOMPARTMENTAL ANALYSIS TO PROBLEMS OF CLINICAL MEDICINE - COMBINED CLINICAL STAFF CONFERENCE AT NATIONAL INSTITUTES OF HEALTH [J].
BERLIN, NI ;
BERMAN, M ;
BERK, PD ;
PHANG, JM ;
WALDMANN, TA .
ANNALS OF INTERNAL MEDICINE, 1968, 68 (02) :423-+
[4]
DAGHIGHIAN F, 1993, EUR J NUCL MED, V20, P402
[5]
PROGRAM PACKAGE FOR SIMULATION AND PARAMETER-ESTIMATION IN PHARMACOKINETIC SYSTEMS [J].
DARGENIO, DZ ;
SCHUMITZKY, A .
COMPUTER PROGRAMS IN BIOMEDICINE, 1979, 9 (02) :115-134
[6]
EGER RR, 1987, CANCER RES, V47, P3328
[7]
FOSTER DM, 1983, COMPARTMENTAL DISTRI, P73
[8]
USE OF RADIOLABELED ANTIBODIES TO CARCINOEMBRYONIC ANTIGEN FOR DETECTION AND LOCALIZATION OF DIVERSE CANCERS BY EXTERNAL PHOTOSCANNING [J].
GOLDENBERG, DM ;
DELAND, F ;
KIM, E ;
BENNETT, S ;
PRIMUS, FJ ;
VANNAGELL, JR ;
ESTES, N ;
DESIMONE, P ;
RAYBURN, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1978, 298 (25) :1384-1388
[9]
HALPERN SE, 1983, CANCER RES, V43, P5347
[10]
HIDEHIRO I, 1993, J NUCL MED, V34, P1333