EDGE-DETECTION VERSUS VIDEODENSITOMETRY FOR QUANTITATIVE ANGIOGRAPHIC ASSESSMENT OF DIRECTIONAL CORONARY ATHERECTOMY

被引:20
作者
UMANS, VA
STRAUSS, BH
DEFEYTER, PJ
SERRUYS, PW
机构
[1] Catheterization Laboratory, Thoraxcenter, University Hospital Dijkzigt
[2] Erasmus University Rotterdam, 3000 DR Rotterdam
关键词
D O I
10.1016/0002-9149(91)90793-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The immediate efficacy of coronary atherectomy should be established by reproducible quantitative coronary analysis.1 The term "directional atherectomy" suggests that the device can be selectively directed toward the plaque and that its cutting mechanism is potentially less disruptive on vascular architecture than other angioplasty modalities. As a result of this selectively debulking action, the vessel may assume a more circular configuration, and cross-sectional area measurements obtained by edge detection and videodensitometry should become more comparable. This study was undertaken to determine whether videodensitometry and edge detection were equally acceptable methods in assessing the immediate results after atherectomy since the optimal method has not yet been established. Cineangiograms of 20 patients who underwent directional coronary atherectomy were analyzed with a computer-based coronary angiographic analysis system. The results of the cross-sectional area derived from contour analysis and videodensitometry were compared before and after directional atherectomy. © 1991.
引用
收藏
页码:534 / 539
页数:6
相关论文
共 11 条
[1]   RESTENOSIS AFTER CORONARY ANGIOPLASTY - NEW STANDARDS FOR CLINICAL-STUDIES [J].
BEATT, KJ ;
SERRUYS, PW ;
HUGENHOLTZ, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) :491-498
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Reiber J H, 1984, IEEE Trans Med Imaging, V3, P131, DOI 10.1109/TMI.1984.4307669
[4]   ASSESSMENT OF SHORT-TERM, MEDIUM-TERM, AND LONG-TERM VARIATIONS IN ARTERIAL DIMENSIONS FROM COMPUTER-ASSISTED QUANTITATION OF CORONARY CINEANGIOGRAMS [J].
REIBER, JHC ;
SERRUYS, PW ;
KOOIJMAN, CJ ;
WIJNS, W ;
SLAGER, CJ ;
GERBRANDS, JJ ;
SCHUURBIERS, JCH ;
DENBOER, A ;
HUGENHOLTZ, PG .
CIRCULATION, 1985, 71 (02) :280-288
[5]  
REIBER JHC, 1983, DIGITAL IMAGING CARD, P89
[6]  
REIBER JHC, 1991, CARDIAC IMAGING COMP, P213
[7]  
REIBER JHC, 1986, QUANTITATIVE CORONAR, P1
[8]  
RENSING B, 1990, Journal of the American College of Cardiology, V15, p43A
[9]   ADDITIONAL IMPROVEMENT OF STENOSIS GEOMETRY IN HUMAN CORONARY-ARTERIES BY STENTING AFTER BALLOON DILATATION [J].
SERRUYS, PW ;
JULLIERE, Y ;
BERTRAND, ME ;
PUEL, J ;
RICKARDS, AF ;
SIGWART, U .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (14) :G71-G76
[10]   ASSESSMENT OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY BY QUANTITATIVE CORONARY ANGIOGRAPHY - DIAMETER VERSUS DENSITOMETRIC AREA MEASUREMENTS [J].
SERRUYS, PW ;
REIBER, JHC ;
WIJNS, W ;
VANDERBRAND, M ;
KOOIJMAN, CJ ;
TENKATEN, HJ ;
HUGENHOLTZ, PG .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (06) :482-488