CARBON-MONOXIDE PRODUCTION FROM DEGRADATION OF DESFLURANE, ENFLURANE, ISOFLURANE, HALOTHANE, AND SEVOFLURANE BY SODA LIME AND BARALYME(R)

被引:138
作者
FANG, ZX [1 ]
EGER, EI [1 ]
LASTER, MJ [1 ]
CHORTKOFF, BS [1 ]
KANDEL, L [1 ]
IONESCU, P [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT ANESTHESIA,SAN FRANCISCO,CA 94143
关键词
D O I
10.1097/00000539-199506000-00021
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Anecdotal reports suggest that soda lime and Baralyme(R) brand absorbent can degrade inhaled anesthetics to carbon monoxide (GO). We examined the factors that govern CO production and found that these include: 1) The anesthetic used: for a given minimum alveolar anesthetic concentration (MAC)-multiple, the magnitude of CO production (greatest to least) is desflurane greater than or equal to enflurane > isoflurane >> halothane = sevoflurane. 2) The absorbent dryness: completely dry soda lime produces much more CO than absorbent with just 1.4% water content, and soda lime containing 4.8% or more water (standard soda lime contains 15% water) generates no CO. In contrast, both completely dry Baralyme(R) and Baralyme(R) with 1.6% water produce high concentrations of CO, and Baralyme(R) containing 4.7% water produces concentrations equaling those produced by soda Lime containing 1.4% water. Baralyme(R) containing 9.7% or more water and standard Baralyme(R) (13% water) do not generate CO. 3) The type of absorbent: at a given water content, Baralyme(R) produces more CO than does soda lime. 4) The temperature: an increased temperature increases CO production. 5) The anesthetic concentration: more CO is produced from higher anesthetic concentrations. These results suggest that CO generation can be avoided for all anesthetics by using soda lime with 4.8% (or more) water or Baralyme(R) with 9.7% (or more) water, and by using inflow rates of less than 2-3 L/min. Such inflow rates are low enough to ensure that the absorbent does not dry out.
引用
收藏
页码:1187 / 1193
页数:7
相关论文
共 13 条
[1]  
ADRIANI J, 1942, ANESTHESIOLOGY, V3, P1
[2]  
ANDREWS J, 1994, INHALED ANESTHETIC D, P195
[3]   EFFECTS OF INFLOW OVERFLOW AND VALVE PLACEMENT ON ECONOMY OF CIRCLE SYSTEM [J].
EGER, EI ;
ETHANS, CT .
ANESTHESIOLOGY, 1968, 29 (01) :93-&
[4]  
Fang Z, 1994, ANESTHESIA PATIENT S, V9, P25
[5]  
HARPER M, 1976, ANESTH ANALG, V55, P724
[6]  
LENTZ R, 1994, ANESTH PATIENT SAFET, V9, P13
[7]  
MIDDLETON V, 1963, ANESTHESIOLOGY, V26, P715
[8]  
MOON R, 1994, ANESTH PATIENT SAFET, V9, P13
[9]  
MOON R, 1990, ANESTHESIOLOGY, V73, pA1049
[10]  
Moon RE, 1991, ANESTHESIOLOGY, V75, pA873