A COMPUTER ALGORITHM FOR DIFFERENTIATING VALID FROM DISTORTED PULSE OXIMETER WAVE-FORMS IN NEONATES

被引:5
作者
ADAMS, JA
INMAN, IM
ABREU, SA
ZABALETA, IA
SACKNER, MA
机构
[1] MT SINAI MED CTR,DIV PULM DIS,MIAMI BEACH,FL 33140
[2] NONINVAS MONITORING SYST INC,MIAMI BEACH,FL
关键词
PULSE OXIMETRY; ARTERIAL OXYGEN SATURATION; PULSE WAVE-FORM; NEWBORN;
D O I
10.1002/ppul.1950190510
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Current pulse oximeter technology is fraught with a significant false alarm rate. This is mainly due to motion artifacts at the sensor site which distort the pulse waveform and render the computation of SaO(2) invalid. If the pulse waveform could be automatically recognized as either normal or distorted, then only valid SaO(2) values would be displayed. We observed that the systolic upstroke time (Sy) of the pulse waveform has a narrow and consistent range in normal appearing pulses. The systolic upstroke time (Sy) is the time from the onset of systole to the peak of the pulse waveform. Comparison of a preset range of Sy was made against Sy obtained by computer analysis of each pulse waveform. Visual examination of 14,090 pulses was carried out to determine the sensitivity and false positive rate of the algorithm. Sensitivity of computer detection of valid pulses was 92% with a positive predictive value of 92%. When used on line for continuous recording of SaO(2) in patients, this simple algorithm has the potential to decrease the false alarm rate of pulse oximeters and improve the accuracy of long-term SaO(2) recordings. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 10 条
[1]  
ALEXANDER CM, 1989, ANESTH ANALG, V68, P368
[2]  
BAHN AK, 1972, BASIC MED STATISTICS, P184
[3]  
HON EH, 1993, J MATERN FETAL MED, V2, P179
[4]  
HON EH, 1993, J MATERN FETAL MED, V2, P97
[5]   ROUTINE OXIMETRY - A 5TH VITAL SIGN [J].
NEFF, TA .
CHEST, 1988, 94 (02) :227-227
[6]   MONITORING NEONATAL PERIPHERAL-CIRCULATION BY ELECTROCARDIOGRAM-TO-OXIMETER PULSE VELOCITY [J].
OISHI, M ;
NISHIDA, H ;
KABE, K ;
HOSHI, J .
PEDIATRIC RESEARCH, 1993, 33 (06) :653-657
[7]  
SADEH A, 1991, PEDIATRICS, V87, P494
[8]   PULSE OXIMETRY - USES AND ABUSES [J].
SCHNAPP, LM ;
COHEN, NH .
CHEST, 1990, 98 (05) :1244-1250
[9]   ERRORS IN 14 PULSE OXIMETERS DURING PROFOUND HYPOXIA [J].
SEVERINGHAUS, JW ;
NAIFEH, KH ;
KOH, SO .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (02) :72-81
[10]   PULSE OXIMETRY - ANALYSIS OF THEORY, TECHNOLOGY, AND PRACTICE [J].
WUKITSCH, MW ;
PETTERSON, MT ;
TOBLER, DR ;
POLOGE, JA .
JOURNAL OF CLINICAL MONITORING, 1988, 4 (04) :290-301