COLOR DOPPLER ULTRASOUND ASSESSMENT OF ARTERIOVENOUS HEMODIALYSIS FISTULAS

被引:57
作者
NONNASTDANIEL, B
MARTIN, RP
LINDERT, O
MUGGE, A
SCHAEFFER, J
SOCHTIG, E
GALANSKI, M
KOCH, KM
DANIEL, WG
VANDERLIETH, H
机构
[1] HANOVER MED SCH,DEPT INTERNAL MED,DIV CARDIOL,W-3000 HANNOVER,GERMANY
[2] HANOVER MED SCH,DEPT CARDIOVASC SURG,W-3000 HANNOVER,GERMANY
[3] HANOVER MED SCH,DEPT RADIOL,W-3000 HANNOVER,GERMANY
[4] EMORY UNIV,SCH MED,DIV CARDIOL,ATLANTA,GA 30322
关键词
D O I
10.1016/0140-6736(92)90209-L
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Satisfactory function of the arteriovenous fistula (AVF) is essential for adequate haemodialysis in patients with chronic renal failure. Existing methods to assess AVF function are imprecise (eg, clinical examination) or invasive (eg, angiography). We assessed the value of colour flow-doppler ultrasound (CFDU) in the investigation of clinically suspected AVF dysfunction. 51 patients with suspected impairment of AVF function were studied by CFDU, and 28 also underwent angiography. The findings were compared with the reference standard of the findings at reoperation. CFDU showed AVF stenoses in 1 8 patients, which were all confirmed at reoperation; the results of angiography in 13 of these 18 patients showed complete agreement with the findings of CFDU and surgery. CFDU showed partial or complete AVF thrombosis in 33 patients, confirmed in all patients at reoperation; 1 5 patients also underwent angiography, and thrombi were not found in 6 (in 4 because of technical failure). 7 patients had aneurysms on CFDU that were confirmed by surgery in all patients and by angiography in 2 of the 3 patients studied. CFDU enables reliable non-invasive assessment of AVF morphology and function and may become the procedure of choice for AVF assessment in patients with suspected AVF abnormalities.
引用
收藏
页码:143 / 145
页数:3
相关论文
共 11 条
[1]  
BERGMANN H, 1982, WIEN MED WOCHENSCHR, V11, P245
[2]   CHRONIC HEMODIALYSIS USING VENIPUNCTURE AND A SURGICALLY CREATED ARTERIOVENOUS FISTULA [J].
BRESCIA, MJ ;
CIMINO, JE ;
APPEL, K ;
HURWICH, BJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1966, 275 (20) :1089-&
[3]   QUANTITATIVE FLOW ESTIMATIONS OF ARTERIOVENOUS-FISTULAS WITH DOPPLER AND DYE-DILUTION TECHNIQUES [J].
FORSBERG, L ;
TYLEN, U ;
OLIN, T ;
LINDSTEDT, E .
ACTA RADIOLOGICA-DIAGNOSIS, 1980, 21 (04) :465-468
[4]   DUPLEX SONOGRAPHY - A NON-INVASIVE METHOD FOR THE EVALUATION OF THE MORPHOLOGY AND THE FUNCTION OF HEMODIALYSIS VASCULAR ACCESS [J].
KATHREIN, H ;
KONIG, P ;
WEIMANN, S ;
JUDMAIER, G ;
DITTRICH, P .
ULTRASCHALL IN DER MEDIZIN, 1989, 10 (01) :33-40
[5]   COLOR DOPPLER SONOGRAPHY OF HEMODIALYSIS VASCULAR ACCESS - COMPARISON WITH ANGIOGRAPHY [J].
MIDDLETON, WD ;
PICUS, DD ;
MARX, MV ;
MELSON, GL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :633-639
[6]  
OREILLY RJ, 1978, AJR, V140, P1105
[7]  
RIEDHAMMER HH, 1988, NIEREN HOCHDRUCK, V17, P85
[8]   HIGH-RESOLUTION REAL-TIME SONOGRAPHY OF HEMODIALYSIS VASCULAR ACCESS COMPLICATIONS [J].
SCHEIBLE, W ;
SKRAM, C ;
LEOPOLD, GR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (06) :1173-1176
[9]   COMPLICATIONS OF ASCENDING PHLEBOGRAPHY OF LEG [J].
THOMAS, ML ;
MACDONALD, LM .
BRITISH MEDICAL JOURNAL, 1978, 2 (6133) :317-318
[10]  
VILLEMARETTE PA, 1989, J VASC TECHNOL, V13, P164