学术探索
学术期刊
新闻热点
数据分析
智能评审
立即登录
ANTIMICROBIAL SUSCEPTIBILITY TESTING OF HAEMOPHILUS-INFLUENZAE IMPROVEMENT OF ACCURACY OF THE DISK DIFFUSION TEST
被引:16
作者
:
RINGERTZ, S
论文数:
0
引用数:
0
h-index:
0
机构:
KAROLINSKA HOSP,S-10401 STOCKHOLM 60,SWEDEN
RINGERTZ, S
OLSSONLILJEQUIST, B
论文数:
0
引用数:
0
h-index:
0
机构:
KAROLINSKA HOSP,S-10401 STOCKHOLM 60,SWEDEN
OLSSONLILJEQUIST, B
KRONVALL, G
论文数:
0
引用数:
0
h-index:
0
机构:
KAROLINSKA HOSP,S-10401 STOCKHOLM 60,SWEDEN
KRONVALL, G
机构
:
[1]
KAROLINSKA HOSP,S-10401 STOCKHOLM 60,SWEDEN
[2]
NATL BACTERIOL LAB,DEPT BACTERIOL,S-10521 STOCKHOLM,SWEDEN
来源
:
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY
|
1990年
/ 26卷
/ 04期
关键词
:
D O I
:
10.1093/jac/26.4.479
中图分类号
:
R51 [传染病];
学科分类号
:
100401 ;
摘要
:
A national quality control study was performed in 1986 to investigate the standard of performance of the disc diffusion antimicrobial susceptibility testing of Haemophilus influenzae in Sweden. The accuracy of susceptibility interpretations was unacceptably low. A new standardized method for susceptibility testing of H. influenzae was then worked out, and a new method of setting interpretive zone breakpoints was introduced. The susceptibility category of the main population of clinical isolates was determined according to the MIC50 of the strains. The zone histograms of clinical isolates from five reference laboratories were used for the calculation of interpretive breakpoints. For instance, for susceptible strains the mean of the combined zone values from these laboratories ± 2 s.D. covered the zone range of the susceptible group, and one more s.D. below covered the intermediate/indeterminate group. The new zone breakpoints would place the main population of clinical isolates in the correct susceptibility group, and even make it possible to detect strains with different degrees of reduced susceptibility in the routine test. In a follow-up quality control study in 1988 the interpretive errors for clinical isolates were eliminated for all antibiotics except doxycycline in some laboratories. Laboratory-related zone breakpoints for doxycycline calculated by the single strain regression analysis method led to correct susceptibility interpretations also in these cases. © 1990 by The British Society for Antimicrobial Chemotherapy.
引用
收藏
页码:479 / 489
页数:11
相关论文
共 6 条
[1]
BJORKLIND A, 1989, APMIS, V97, P941
[2]
ANALYSIS OF A SINGLE REFERENCE STRAIN FOR DETERMINATION OF GENTAMICIN REGRESSION LINE CONSTANTS AND INHIBITION ZONE DIAMETER BREAKPOINTS IN QUALITY-CONTROL OF DISK DIFFUSION ANTIBIOTIC SUSCEPTIBILITY TESTING
KRONVALL, G
论文数:
0
引用数:
0
h-index:
0
KRONVALL, G
[J].
JOURNAL OF CLINICAL MICROBIOLOGY,
1982,
16
(05)
: 784
-
793
[3]
ACCURACY OF METHODS USED FOR SUSCEPTIBILITY TESTING OF HEMOPHILUS-INFLUENZAE IN UNITED-KINGDOM LABORATORIES
PHILPOTTHOWARD, J
论文数:
0
引用数:
0
h-index:
0
PHILPOTTHOWARD, J
SEYMOUR, A
论文数:
0
引用数:
0
h-index:
0
SEYMOUR, A
WILLIAMS, JD
论文数:
0
引用数:
0
h-index:
0
WILLIAMS, JD
[J].
JOURNAL OF CLINICAL PATHOLOGY,
1983,
36
(10)
: 1105
-
1110
[4]
ANTIMICROBIAL SUSCEPTIBILITY TESTING OF HAEMOPHILUS-INFLUENZAE - TRIAL ORGANIZED AS PART OF UNITED-KINGDOM NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEME FOR MICROBIOLOGY
SNELL, JJS
论文数:
0
引用数:
0
h-index:
0
机构:
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
SNELL, JJS
BROWN, DFJ
论文数:
0
引用数:
0
h-index:
0
机构:
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
BROWN, DFJ
PHUA, TJ
论文数:
0
引用数:
0
h-index:
0
机构:
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
PHUA, TJ
[J].
JOURNAL OF CLINICAL PATHOLOGY,
1986,
39
(09)
: 1006
-
1012
[5]
Thornsberry C., 1987, Antimicrobic Newsletter, V4, P47, DOI 10.1016/0738-1751(87)90026-8
[6]
1988, NCCLS M2 T4 NAT COMM
←
1
→
共 6 条
[1]
BJORKLIND A, 1989, APMIS, V97, P941
[2]
ANALYSIS OF A SINGLE REFERENCE STRAIN FOR DETERMINATION OF GENTAMICIN REGRESSION LINE CONSTANTS AND INHIBITION ZONE DIAMETER BREAKPOINTS IN QUALITY-CONTROL OF DISK DIFFUSION ANTIBIOTIC SUSCEPTIBILITY TESTING
KRONVALL, G
论文数:
0
引用数:
0
h-index:
0
KRONVALL, G
[J].
JOURNAL OF CLINICAL MICROBIOLOGY,
1982,
16
(05)
: 784
-
793
[3]
ACCURACY OF METHODS USED FOR SUSCEPTIBILITY TESTING OF HEMOPHILUS-INFLUENZAE IN UNITED-KINGDOM LABORATORIES
PHILPOTTHOWARD, J
论文数:
0
引用数:
0
h-index:
0
PHILPOTTHOWARD, J
SEYMOUR, A
论文数:
0
引用数:
0
h-index:
0
SEYMOUR, A
WILLIAMS, JD
论文数:
0
引用数:
0
h-index:
0
WILLIAMS, JD
[J].
JOURNAL OF CLINICAL PATHOLOGY,
1983,
36
(10)
: 1105
-
1110
[4]
ANTIMICROBIAL SUSCEPTIBILITY TESTING OF HAEMOPHILUS-INFLUENZAE - TRIAL ORGANIZED AS PART OF UNITED-KINGDOM NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEME FOR MICROBIOLOGY
SNELL, JJS
论文数:
0
引用数:
0
h-index:
0
机构:
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
SNELL, JJS
BROWN, DFJ
论文数:
0
引用数:
0
h-index:
0
机构:
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
BROWN, DFJ
PHUA, TJ
论文数:
0
引用数:
0
h-index:
0
机构:
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
ADDENBROOKES HOSP, CLIN MICROBIOL & PUBL HLTH LAB, CAMBRIDGE CB2 2QQ, ENGLAND
PHUA, TJ
[J].
JOURNAL OF CLINICAL PATHOLOGY,
1986,
39
(09)
: 1006
-
1012
[5]
Thornsberry C., 1987, Antimicrobic Newsletter, V4, P47, DOI 10.1016/0738-1751(87)90026-8
[6]
1988, NCCLS M2 T4 NAT COMM
←
1
→