COMPARISON BETWEEN TAPE-RECORDED AND AMPLITUDE-INTEGRATED EEG MONITORING IN SICK NEWBORN-INFANTS

被引:86
作者
HELLSTROMWESTAS, L [1 ]
机构
[1] UNIV LUND, DEPT PAEDIAT, NEONATAL INTENS CARE UNIT, S-22101 LUND, SWEDEN
关键词
D O I
10.1111/j.1651-2227.1992.tb12109.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
In 15 ill newborn infants a comparison between long-term multichannel and single-channel recordings of simultaneously tape-recorded (Medilog system) and amplitude-integrated EEG (Cerebral Function Monitor) was made. There was good agreement between the main type of background activity diagnosed with the tape-recorded and the amplitude-integrated EEG for all recordings. Two infants had repetitive subclinical and subtle seizure activity, lasting for several hours, which was detected by both techniques. Short, single seizures were diagnosed in the recordings of nine infants. When a single electrographic seizure appeared in an otherwise stable recording, it was identified by both the tape-recorded and the amplitude-integrated EEG. Very short (5-30 s) seizure patterns, which were diagnosed with the tape-recorded EEG, were not identified in the cerebral function monitor recordings. In the single-channel recordings of both the EEG and the cerebral function monitor there were, on some occasions, difficulties in distinguishing single seizures from interference due to external artefacts. In the multichannel recordings the diagnosis of seizure patterns was facilitated by comparison with the other channels. Both the Medilog EEG and the cerebral function monitor are feasible techniques for following cerebral electrical activity in sick neonates, although neither technique is specifically constructed for this purpose. For clinical use in the neonatal intensive care unit the advantage with the cerebral function monitor is the immediately available recording. The tape-recorded EEG offers possibilities of more channels and a higher reliability when diagnosing short subclinical seizures, however, only after offline analysis.
引用
收藏
页码:812 / 819
页数:8
相关论文
共 23 条
  • [1] MONITORING OF CEREBRAL FUNCTION AFTER SEVERE ASPHYXIA IN INFANCY
    BJERRE, I
    HELLSTROMWESTAS, L
    ROSEN, I
    SVENNINGSEN, N
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1983, 58 (12) : 997 - 1002
  • [2] OCCULT NEONATAL SEIZURES
    CLANCY, RR
    LEGIDO, A
    LEWIS, D
    [J]. EPILEPSIA, 1988, 29 (03) : 256 - 261
  • [3] CONTINUOUS MONITORING OF THE ELECTROENCEPHALOGRAM FOLLOWING PERINATAL ASPHYXIA
    COEN, RW
    MCCUTCHEN, CB
    WERMER, D
    SNYDER, J
    GLUCK, FE
    [J]. JOURNAL OF PEDIATRICS, 1982, 100 (04) : 628 - 630
  • [4] CONNELL J, 1988, PEDIATRICS, V82, P337
  • [5] CONTINUOUS 4-CHANNEL EEG MONITORING - A GUIDE TO INTERPRETATION, WITH NORMAL VALUES, IN PRETERM INFANTS
    CONNELL, JA
    OOZEER, R
    DUBOWITZ, V
    [J]. NEUROPEDIATRICS, 1987, 18 (03) : 138 - 145
  • [6] EYRE JA, 1988, DEV MED CHILD NEUROL, V30, P599
  • [7] DIAGNOSIS OF NEONATAL SEIZURE BY CONTINUOUS RECORDING AND RAPID ANALYSIS OF THE ELECTROENCEPHALOGRAM
    EYRE, JA
    OOZEER, RC
    WILKINSON, AR
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1983, 58 (10) : 785 - 790
  • [8] EEG DEPRESSION AND GERMINAL LAYER HEMORRHAGE IN THE NEWBORN
    GREISEN, G
    HELLSTROMWESTAS, L
    LOU, H
    ROSEN, I
    SVENNINGSEN, NW
    [J]. ACTA PAEDIATRICA SCANDINAVICA, 1987, 76 (03): : 519 - 525
  • [9] SILENT SEIZURES IN SICK INFANTS IN EARLY LIFE - DIAGNOSIS BY CONTINUOUS CEREBRAL FUNCTION MONITORING
    HELLSTROMWESTAS, L
    ROSEN, I
    SWENNINGSEN, NW
    [J]. ACTA PAEDIATRICA SCANDINAVICA, 1985, 74 (05): : 741 - 748
  • [10] CEREBRAL FUNCTION MONITORING DURING THE 1ST WEEK OF LIFE IN EXTREMELY SMALL LOW-BIRTH-WEIGHT (ESLBW) INFANTS
    HELLSTROMWESTAS, L
    ROSEN, I
    SVENNINGSEN, NW
    [J]. NEUROPEDIATRICS, 1991, 22 (01) : 27 - 32