DETERMINATION OF METHOTREXATE AND 7-HYDROXYMETHOTREXATE BY LIQUID-CHROMATOGRAPHY FOR ROUTINE MONITORING OF PLASMA-LEVELS

被引:34
作者
COCIGLIO, M
HILLAIREBUYS, D
ALRIC, C
机构
[1] CHU MONTPELLIER,HOP ST CHARLES,PHARMACOL CLIN LAB,F-34295 MONTPELLIER 05,FRANCE
[2] CHU MONTPELLIER,HOP ST CHARLES,CTR REG PHARMACOVIGILANCE,F-34295 MONTPELLIER 05,FRANCE
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 674卷 / 01期
关键词
D O I
10.1016/0378-4347(95)00301-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatographic (HPLC) method was designed to meet analytical and metrological requirements for routine blood level monitoring of methotrexate (MTX) and its main metabolite 7-hydroxy-methotrexate (7OMTX). The metabolite, unavailable as a pure substance, was measured by reference to MTX calibration according to their respective ultraviolet absorbances. Acetonitrile deproteinization and chloroform clean-up provided plasma samples devoid of long-retained contaminants. The precision of the HPLC measurements, reproducibility of clean-up recovery, matrix effects and linearity were assessed by analysis of variance and linear regression in an appropriate experimental design,within a range from 0.205 to 16.7 mg/l of MTX and from 0.084 to 6.83 mg/l of 7OMTX. The clean-up recovery from plasma was 88% for MTX and 72% for 7OMTX, owing to retention on the protein precipitate. The assay was linear, the measurement precision was 3.3% for MTX and 6.2% for 7OMTX and the clean-up reproducibility was 4% for MTX and 3.6% for 7OMTX. By reference to automated fluorescence polarization immunoassay, the HPLC method resulted in plasma MTX values 10% lower, probably owing to the higher specificity of HPLC. Unsystematically sequenced plasma samples from 35 children following 24-h MTX infusions provided estimated half-decay times of 16 and 19 h for MTX and 7OMTX, respectively, and 7OMTX:MTX concentration ratios of 7 at 48 h and of 5 at 72 h from starting infusions.
引用
收藏
页码:101 / 110
页数:10
相关论文
共 16 条
[1]   PERFORMANCE EVALUATION OF A REVERSED-PHASE, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF VALPROIC ACID INVOLVING A SOLVENT DEMIXING EXTRACTION PROCEDURE AND PRECOLUMN DERIVATIZATION [J].
ALRIC, R ;
COCIGLIO, M ;
BLAYAC, JP ;
PUECH, R .
JOURNAL OF CHROMATOGRAPHY, 1981, 224 (02) :289-299
[2]  
ALRIC R, 1984, METHOD FIND EXP CLIN, V7, P353
[3]  
ANAYA JM, 1994, J RHEUMATOL, V21, P203
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR SERUM METHOTREXATE LEVELS IN CHILDREN WITH SEVERE STEROID-DEPENDENT ASTHMA [J].
ASSADULLAHI, TP ;
DAGLI, E ;
WARNER, JO .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 565 (1-2) :349-356
[5]   TRACE ANALYSIS OF METHOTREXATE AND 7-HYDROXYMETHOTREXATE IN HUMAN PLASMA AND URINE BY A NOVEL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD [J].
BECK, O ;
SEIDEMAN, P ;
WENNBERG, M ;
PETERSON, C .
THERAPEUTIC DRUG MONITORING, 1991, 13 (06) :528-532
[6]  
Chamberlin A.R., 1976, METHOTREXATE, V5, P283
[7]   SYNTHESIS AND BIOLOGIC EVALUATION OF 7-HYDROXYMETHOTREXATE, 7-METHYLAMINOPTERIN, AND 7-METHYLMETHOTREXATE [J].
FARQUHAR, D ;
LOO, TL .
JOURNAL OF MEDICINAL CHEMISTRY, 1972, 15 (05) :567-&
[8]  
LINNET K, 1993, CLIN CHEM, V39, P424
[9]  
MARTIN LJ, 1973, INT ENCY PHARM THERA, V7, P544
[10]   RAPID QUANTITATION OF METHOTREXATE AND ITS METABOLITES IN HUMAN-SERUM, URINE AND BILE, USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
NUERNBERG, B ;
KOHLBRENNER, M ;
FAULKNER, R ;
FURST, DE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (02) :476-482