DETERMINATION OF FLUORINE IN URINE AND TAP WATER BY LASER-EXCITED MOLECULAR FLUORESCENCE SPECTROMETRY IN A GRAPHITE TUBE FURNACE WITH FRONT-SURFACE ILLUMINATION

被引:16
作者
BUTCHER, DJ [1 ]
IRWIN, RL [1 ]
TAKAHASHI, J [1 ]
MICHEL, RG [1 ]
机构
[1] UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06269
关键词
LASER-EXCITED MOLECULAR FLUORESCENCE SPECTROMETRY; ELECTROTHERMAL ATOMIZER; FLUORINE DETERMINATION;
D O I
10.1039/ja9910600009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorine was determined in urine and tap water using laser-excited molecular fluorescence spectrometry (LEMOFS) with an unmodified atomic absorption graphite tube furnace. Molecular fluorescence from magnesium fluoride (excited at 268.94 nm, detected at 358.82 nm) was collected using front-surface illumination and detection. A frequency doubled excimer pumped dye laser operating at 500 Hz was used for excitation. This is the first report of the use of front-surface illumination for molecular fluorescence. After optimization of the chemical, furnace and laser conditions, the detection limit of 0.3 pg of fluorine (as fluoride) was from two to six orders of magnitude better than other methods commonly used for the determination of fluorine, and two orders of magnitude more sensitive than the best previously reported LEMOFS detection limit. The linear dynamic range of the technique was five orders of magnitude. Significant interferences from other ions (Na+, H+, Cl-, B-) were observed. The sensitivity for the determination of fluorine in a freeze-dried urine standard reference material, and in tap water, by LEMOFS was sufficiently high to allow the samples of be diluted by a factor of 100 to remove the interferences. Good agreement with certified values was obtained, with an analytical precision of 7-11%.
引用
收藏
页码:9 / 18
页数:10
相关论文
共 42 条
[1]  
BOLSHOV MA, 1981, SPECTROCHIM ACTA B, V36, P545
[2]   DETERMINATION OF FLUORIDE BY ATOMIC ABSORPTION SPECTROMETRY [J].
BOND, AM ;
ODONNELL, TA .
ANALYTICAL CHEMISTRY, 1968, 40 (03) :560-&
[3]   LASER-EXCITED ATOMIC FLUORESCENCE SPECTROMETRY IN FLAMES, PLASMAS AND ELECTROTHERMAL ATOMIZERS [J].
BUTCHER, DJ ;
DOUGHERTY, JP ;
PRELI, FR ;
WALTON, AP ;
WEI, GT ;
IRWIN, RL ;
MICHEL, RG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (08) :1059-1078
[5]   DETERMINATION OF FLUORINE IN URINE AND BLOOD-SERUM BY ALUMINUM MONOFLUORIDE MOLECULAR ABSORPTION SPECTROMETRY AND WITH A FLUORIDE-ION SELECTIVE ELECTRODE [J].
CHIBA, K ;
TSUNODA, K ;
HARAGUCHI, H ;
FUWA, K .
ANALYTICAL CHEMISTRY, 1980, 52 (11) :1582-1585
[6]   RESPONSE OF FLUORIDE-ION SELECTIVE ELECTRODE IN ORGANIC-SOLVENTS [J].
COETZEE, JF ;
MARTIN, MW .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2412-2416
[7]  
COTTON FA, 1980, ADV INORGANIC CHEM
[9]   SULFONATED ALIZARIN FLUORINE BLUE (AFBS) .4. CRITICAL COMPARISON OF USE OF AFBS AGAINST ALIZARIN FLUORINE BLUE (AFB) AND FLUORIDE ELECTRODE FOR DETERMINATION OF LOW FLUORIDE CONCENTRATIONS - INTERFERENCES WITH AFBS METHOD AND THEIR REMOVAL [J].
DEANE, SF ;
LEONARD, MA ;
MCKEE, V ;
SVEHLA, G .
ANALYST, 1978, 103 (1232) :1134-1147
[10]   DETERMINATION OF SOME NONMETALS BY USING DIATOMIC MOLECULAR ABSORBANCE IN A HOT GRAPHITE-FURNACE [J].
DITTRICH, K ;
VORBERG, B ;
FUNK, J ;
BEYER, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (2-3) :349-363