SPATIAL SHIFT ALIGNMENT (SSA) - A NEW TECHNIQUE FOR MEASURING CAPILLARY BLOOD VELOCITY IN CAPILLAROSCOPY

被引:7
作者
LENTNER, A
BERGER, F
WIENERT, V
机构
来源
BIOMEDIZINISCHE TECHNIK | 1994年 / 39卷 / 7-8期
关键词
CAPILLARY BLOOD VELOCITY; CAPILLARY PHYSIOLOGY; DIGITAL IMAGE PROCESSING; CAPILLARY MICROSCOPY (CAPILLAROSCOPY);
D O I
10.1515/bmte.1994.39.7-8.170
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new technique (spatial shift alignment [SSA]) for measuring capillary blood velocity in human capillaries in the skin is described. A capillaroscopic image is digitized by means of a frame grabber. Within the lumen of a suitable capillary limb a region of interest known as a slot is placed. At a frame frequency of 25 per second, this slot is copied in a free part of the frame grabber store along a horizontal axis. A static space-time image with light diagonal bands representing the plasma gaps in their passage through the capillary limb is obtained. By determining the gradient of the diagonal bands, a measure of the capillary blood velocity is obtained. The SSA system was validated by means of a simulated model using known fixed velocities between 0 and 1.0 mm/sec (r = 0.979, n = 24). The procedure can be employed with any image processing systems, and enables continuous monitoring of the velocity measurements. Since it is time-saving and just as accurate as the frame-to-frame method, SSA could be widely applied to the measurement of blood cell velocity in capillaroscopy.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 16 条
[2]   RED BLOOD-CELL VELOCITY IN NAILFOLD CAPILLARIES OF MAN MEASURED BY A TELEVISION MICROSCOPY TECHNIQUE [J].
BOLLINGER, A ;
BUTTI, P ;
BARRAS, JP ;
TRACHSLER, H ;
SIEGENTHALER, W .
MICROVASCULAR RESEARCH, 1974, 7 (01) :61-72
[3]  
BOSS C, 1987, INT J MICROCIRC, V6, P15
[4]   DETERMINATION OF RED-BLOOD-CELL OXYGENATION INVIVO BY DUAL VIDEO DENSITOMETRIC IMAGE-ANALYSIS [J].
ELLIS, CG ;
ELLSWORTH, ML ;
PITTMAN, RN .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (04) :H1216-H1223
[5]   APPLICATION OF IMAGE-ANALYSIS FOR EVALUATION OF RED-BLOOD-CELL DYNAMICS IN CAPILLARIES [J].
ELLIS, CG ;
ELLSWORTH, ML ;
PITTMAN, RN ;
BURGESS, WL .
MICROVASCULAR RESEARCH, 1992, 44 (02) :214-225
[6]  
FAGRELL BO, 1990, INT J MICROCIRC C S1, V9, P43
[7]   CAPILLARY FLOW VELOCITY-MEASUREMENTS INVIVO AND INSITU BY TELEVISION METHODS [J].
INTAGLIETTA, M ;
SILVERMAN, NR ;
TOMPKINS, WR .
MICROVASCULAR RESEARCH, 1975, 10 (02) :165-179
[8]   ERROR ANALYSIS, BIOLOGICAL INFLUENCING FACTORS, AND VARIANCE OF PERIUNGUAL VIDEO CAPILLARY MICROSCOPY [J].
JUNG, F ;
TOONEN, H ;
MROWIETZ, C ;
WOLF, S ;
KIESEWETTER, H ;
WENZEL, E ;
GERSONDE, K ;
MULLER, G .
BIOMEDIZINISCHE TECHNIK, 1990, 35 (09) :195-204
[9]   VIDEO CAPILLARY MICROSCOPY - DETERMINATION OF GEOMETRICAL AND DYNAMIC PARAMETERS [J].
JUNG, F ;
WAPPLER, M ;
NUTTGENS, HP ;
KIESEWETTER, H ;
WOLF, S ;
MULLER, G .
BIOMEDIZINISCHE TECHNIK, 1987, 32 (09) :204-213
[10]  
MEIER B, 1978, VASA-J VASCULAR DIS, V7, P194