EQUILIBRIUM (GATED) RADIONUCLIDE EJECTION FRACTION MEASUREMENT IN THE PRESSURE OR VOLUME OVERLOADED RIGHT VENTRICLE - COMPARISON OF 3 METHODS

被引:20
作者
KONSTAM, MA
KAHN, PC
CURRAN, BH
IDOINE, J
WYNNE, J
HOLMAN, BL
机构
[1] TUFTS UNIV,SCH MED,DEPT MED,BOSTON,MA 02111
[2] TUFTS UNIV,SCH MED,DEPT RADIOL,BOSTON,MA 02111
[3] HARVARD UNIV,BOSTON,MA 02115
[4] BRIGHAM & WOMENS HOSP,BOSTON,MA 02115
关键词
D O I
10.1378/chest.86.5.681
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
引用
收藏
页码:681 / 687
页数:7
相关论文
共 20 条
[1]  
[Anonymous], CARDIAC CATHETERIZAT
[2]   QUANTITATIVE RADIONUCLIDE ANGIOCARDIOGRAPHY - DETECTION AND QUANTITATION OF LEFT TO RIGHT SHUNTS [J].
ASKENAZI, J ;
AHNBERG, DS ;
KORNGOLD, E ;
LAFARGE, CG ;
MALTZ, DL ;
TREVES, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1976, 37 (03) :382-387
[3]   ASSESSMENT OF RIGHT VENTRICULAR-FUNCTION DURING SUPINE BICYCLE EXERCISE AFTER MUSTARDS OPERATION [J].
BENSON, LN ;
BONET, J ;
MCLAUGHLIN, P ;
OLLEY, PM ;
FEIGLIN, D ;
DRUCK, M ;
TRUSLER, G ;
ROWE, RD ;
MORCH, J .
CIRCULATION, 1982, 65 (06) :1052-1059
[4]   ASSESSMENT OF CARDIAC-PERFORMANCE WITH QUANTITATIVE RADIONUCLIDE ANGIOCARDIOGRAPHY - RIGHT VENTRICULAR EJECTION FRACTION WITH REFERENCE TO FINDINGS IN CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
BERGER, HJ ;
MATTHAY, RA ;
LOKE, J ;
MARSHALL, RC ;
GOTTSCHALK, A ;
ZARET, BL .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (05) :897-905
[5]   PHYSIOLOGIC CORRELATES OF RIGHT VENTRICULAR EJECTION FRACTION IN CHRONIC OBSTRUCTIVE PULMONARY-DISEASE - A COMBINED RADIONUCLIDE AND HEMODYNAMIC-STUDY [J].
BRENT, BN ;
BERGER, HJ ;
MATTHAY, RA ;
MAHLER, D ;
PYTLIK, L ;
ZARET, BL .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (02) :255-262
[6]   IMPROVED RIGHT VENTRICULAR-FUNCTION AND REDUCED PULMONARY VASCULAR-RESISTANCE DURING PRAZOSIN THERAPY OF CONGESTIVE HEART-FAILURE [J].
COLUCCI, WS ;
HOLMAN, BL ;
WYNNE, J ;
CARABELLO, B ;
MALACOFF, R ;
GROSSMAN, W ;
BRAUNWALD, E .
AMERICAN JOURNAL OF MEDICINE, 1981, 71 (01) :75-80
[7]   NON-GEOMETRIC DETERMINATION OF RIGHT VENTRICULAR VOLUMES FROM EQUILIBRIUM BLOOD POOL SCANS [J].
DEHMER, GJ ;
FIRTH, BG ;
HILLIS, LD ;
NICOD, P ;
WILLERSON, JT ;
LEWIS, SE .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (01) :78-84
[8]   A SIMPLIFIED TECHNIQUE FOR MEASURING RIGHT VENTRICULAR EJECTION FRACTION USING THE EQUILIBRIUM RADIONUCLIDE ANGIOCARDIOGRAM AND THE SLANT-HOLE COLLIMATOR [J].
HOLMAN, BL ;
WYNNE, J ;
ZIELONKA, JS ;
IDOINE, JD .
RADIOLOGY, 1981, 138 (02) :429-435
[9]  
HOLMAN BL, 1979, J NUCL MED, V20, P1237
[10]   USE OF EQUILIBRIUM (GATED) RADIONUCLIDE VENTRICULOGRAPHY TO QUANTITATE LEFT-VENTRICULAR OUTPUT IN PATIENTS WITH AND WITHOUT LEFT-SIDED VALVULAR REGURGITATION [J].
KONSTAM, MA ;
WYNNE, J ;
HOLMAN, BL ;
BROWN, EJ ;
NEILL, JM ;
KOZLOWSKI, J .
CIRCULATION, 1981, 64 (03) :578-585