OPTIMIZATION OF THE RADIOIMMUNOASSAYS FOR MEASURING FENTANYL AND ALFENTANIL IN HUMAN-SERUM

被引:83
作者
SCHUTTLER, J [1 ]
WHITE, PF [1 ]
机构
[1] STANFORD UNIV,MED CTR,SCH MED,DEPT ANESTHESIA,STANFORD,CA 94305
关键词
D O I
10.1097/00000542-198409000-00010
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of samples and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: (1) adding the antiserum lastly to the mixture of sample and labeled drug; (2) performing calibration curves using patient's blank serum when possible; (3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; (4) comparing results with those of other established RIA laboratories.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 8 条
[1]
GAS-CHROMATOGRAPHIC DETERMINATION OF FENTANYL AND ITS ANALOGS IN HUMAN-PLASMA [J].
GILLESPIE, TJ ;
GANDOLFI, AJ ;
MAIORINO, RM ;
VAUGHAN, RW .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1981, 5 (03) :133-137
[2]
HENDERSON GL, 1975, J PHARMACOL EXP THER, V192, P489
[3]
SENSITIVE RADIOIMMUNOASSAY FOR FENTANYL - PLASMA-LEVEL IN DOGS AND MAN [J].
MICHIELS, M ;
HENDRIKS, R ;
HEYKANTS, J .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1977, 12 (02) :153-158
[4]
RADIOIMMUNOASSAY OF THE NEW OPIATE ANALGESICS ALFENTANIL AND SUFENTANIL - PRELIMINARY PHARMACOKINETIC PROFILE IN MAN [J].
MICHIELS, M ;
HENDRIKS, R ;
HEYKANTS, J .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1983, 35 (02) :86-93
[5]
MEASUREMENT OF PLASMA FENTANYL CONCENTRATION - COMPARISON OF 3 METHODS [J].
PHIPPS, JA ;
SABOURIN, MA ;
BUCKINGHAM, W ;
STRUNIN, L .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1983, 30 (02) :162-165
[6]
SPRIGGE JS, 1982, ANESTH ANALG, V61, P972
[7]
MORPHINE PHARMACOKINETICS - GLC ASSAY VERSUS RADIOIMMUNOASSAY [J].
STANSKI, DR ;
PAALZOW, L ;
EDLUND, PO .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1982, 71 (03) :314-317
[8]
IMMUNOASSAY OF ENDOGENOUS PLASMA INSULIN IN MAN [J].
YALOW, RS ;
BERSON, SA .
JOURNAL OF CLINICAL INVESTIGATION, 1960, 39 (07) :1157-1175