JOINT FORCES IN THE HUMAN PELVIS LEG SKELETON DURING WALKING

被引:129
作者
ROHRLE, H [1 ]
SCHOLTEN, R [1 ]
SIGOLOTTO, C [1 ]
SOLLBACH, W [1 ]
KELLNER, H [1 ]
机构
[1] UNIV GOTTINGEN,BIOPHOTOGRAMMETRIE ABT,D-3400 GOTTINGEN,FED REP GER
关键词
BIOMEDICAL ENGINEERING - Living Systems Studies - MECHANICAL VARIABLES MEASUREMENT - Forces - OPTIMIZATION - Applications;
D O I
10.1016/0021-9290(84)90033-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
For the calculation of the forces in the hip, knee and ankle joints during walking, knowledge of the three-dimensional movements of the human body and of the forces between foot and ground is a prerequisite. It is shown how this information may be obtained and what accuracy is obtainable. For the calculation of the statically indeterminate system of the lower limbs, consisting of muscles, bones and joints an optimization method is applied. The optimization criterion is the minimization of the muscle forces. Measurements were taken with seventeen male and five female persons. The maximum joint forces are plotted against gait speed, body weight and body size.
引用
收藏
页码:409 / 424
页数:16
相关论文
共 28 条
[1]  
ARCAN M, 1978, J S AFR I ENGRS, V28, P231
[2]  
BAUMANN W, 1975, Z ORTHOP, V113, P636
[3]   A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY [J].
BRAND, RA ;
CROWNINSHIELD, RD ;
WITTSTOCK, CE ;
PEDERSEN, DR ;
CLARK, CR ;
VANKRIEKEN, FM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :304-310
[4]  
BRAUNE W, 1982, ABH KONIGL SACHSI MP, V8
[5]   APPLICATION OF OPTIMIZATION PRINCIPLES IN DETERMINING APPLIED MOMENTS IN HUMAN LEG JOINTS DURING GAIT [J].
CHAO, EY ;
RIM, K .
JOURNAL OF BIOMECHANICS, 1973, 6 (05) :497-510
[6]   DETERMINING MUSCLE FORCES IN LEG DURING NORMAL HUMAN WALKING - APPLICATION AND EVALUATION OF OPTIMIZATION METHODS [J].
HARDT, DE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1978, 100 (02) :72-78
[7]  
HARRINGTON IJ, 1974, TOTAL KNEE REPLACEME, P1
[8]  
MCQUEEN AK, 1979, ANN REPORT OXFORD OR
[9]  
MORRISON JB, 1968, BIOMED ENG, V3, P164
[10]  
PATRIARCO AG, 1981, J BIOMECHANICS, V24, P513