CONTROLLED EVALUATION OF BACTEC PLUS-27 AND ROCHE SEPTI-CHEK ANAEROBIC BLOOD CULTURE BOTTLES

被引:21
作者
WILSON, ML
HARRELL, LJ
MIRRETT, S
WEINSTEIN, MP
STRATTON, CW
RELLER, LB
机构
[1] DUKE UNIV,SCH MED,DEPT MICROBIOL & IMMUNOL,DURHAM,NC 27706
[2] VANDERBILT UNIV,MED CTR,SCH MED,DEPT PATHOL,NASHVILLE,TN 37232
[3] DUKE UNIV,SCH MED,DEPT PATHOL,DURHAM,NC 27706
[4] DUKE UNIV,SCH MED,DEPT MED,DURHAM,NC 27706
[5] VANDERBILT UNIV,MED CTR,MICROBIOL LAB,NASHVILLE,TN 37232
[6] VANDERBILT UNIV,MED CTR,SCH MED,DEPT MED,NASHVILLE,TN 37232
[7] UNIV MED & DENT NEW JERSEY,ROBERT WOOD JOHNSON MED SCH,DEPT MED,NEW BRUNSWICK,NJ 08901
[8] UNIV MED & DENT NEW JERSEY,ROBERT WOOD JOHNSON MED SCH,DEPT PATHOL,NEW BRUNSWICK,NJ 08901
[9] UNIV MED & DENT NEW JERSEY,ROBERT WOOD JOHNSON UNIV HOSP,MICROBIOL LAB,NEW BRUNSWICK,NJ 08901
关键词
D O I
10.1128/JCM.30.1.63-66.1992
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Becton Dickinson Diagnostic Instrument Systems (Sparks, Md.) recently introduced BACTEC high-volume aerobic and anaerobic bottles that accept up to 10 ml of blood for use on their nonradiometric blood culture instruments. Both bottles contain 25 ml of tryptic soy broth, 0.05% sodium polyanetholesulfonate, and mixed resins. We compared the anaerobic bottle, designated BACTEC PLUS 27 (BP27), with the Roche Septi-Chek (RSC) Columbia broth anaerobic bottle in a collaborative evaluation at three university hospitals. A total of 5,152 adequately filled blood cultures were obtained from adult patients with suspected bacteremia or fungemia. Staphylococcus aureus was recovered significantly more often (P < 0.03) from BP27 bottles alone; there were no other significant differences in yield. When microorganisms were recovered from both anaerobic bottles, growth was detected earlier in BP27 than it was in RSC (P < 0.001), especially for S. aureus (P < 0.001) and Staphylococcus epidermidis (P < 0.02). We conclude that the yield from BP27 bottles is equivalent to or better (S. aureus) than that from RSC anaerobic bottles with Columbia broth and that speed of detection is superior with BP27 bottles.
引用
收藏
页码:63 / 66
页数:4
相关论文
共 16 条
[1]   IMPORTANCE OF BLOOD-VOLUME CULTURED IN THE DETECTION OF BACTEREMIA [J].
ARPI, M ;
BENTZON, MW ;
JENSEN, J ;
FREDERIKSEN, W .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1989, 8 (09) :838-842
[2]   COMPARISON OF RECOVERY OF ORGANISMS FROM BLOOD CULTURES DILUTED 10-PERCENT (VOLUME VOLUME) AND 20-PERCENT (VOLUME VOLUME) [J].
AUCKENTHALER, R ;
ILSTRUP, DM ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1982, 15 (05) :860-864
[3]  
DORSHER CW, 1991, REV INFECT DIS, V13, P633
[4]   THE CAUSATIVE ORGANISMS OF SEPTICEMIA AND THEIR EPIDEMIOLOGY [J].
EYKYN, SJ ;
GRANSDEN, WR ;
PHILLIPS, I .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1990, 25 :41-58
[5]  
HALL MM, 1976, J CLIN MICROBIOL, V3, P643
[6]   THE IMPORTANCE OF VOLUME OF BLOOD CULTURED IN THE DETECTION OF BACTEREMIA AND FUNGEMIA [J].
ILSTRUP, DM ;
WASHINGTON, JA .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1983, 1 (02) :107-110
[7]  
JUNGKIND DL, 1989, 1989 ANN M AM SOC C, V225, P431
[8]  
Lennette E.H., 1980, MANUAL CLIN MICROBIO, P195
[9]  
MCNEMAR Q, 1962, PSYCHOL STAT, P209
[10]   SPECIMEN VOLUME VERSUS YIELD IN THE BACTEC BLOOD CULTURE SYSTEM [J].
PLORDE, JJ ;
TENOVER, FC ;
CARLSON, LG .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (02) :292-295