FRACTURE-TOUGHNESS OF HUMAN BONE UNDER TENSION

被引:181
作者
NORMAN, TL
VASHISHTH, D
BURR, DB
机构
[1] W VIRGINIA UNIV,DEPT ORTHOPED,MORGANTOWN,WV 26505
[2] UNIV LONDON QUEEN MARY & WESTFIELD COLL,INTERDISCIPLINARY RES CTR BIOMED MAT,LONDON,ENGLAND
[3] INDIANA UNIV,DEPT ANAT,INDIANAPOLIS,IN
[4] INDIANA UNIV,DEPT ORTHOPED SURG,INDIANAPOLIS,IN
[5] IUPUI,BIOMECH & BIOMAT RES CTR,INDIANAPOLIS,IN 46202
基金
美国国家科学基金会;
关键词
FRACTURE TOUGHNESS; CRACK PROPAGATION; HUMAN BONE; BOVINE BONE; FRACTURE MECHANICS;
D O I
10.1016/0021-9290(94)00069-G
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The longitudinal fracture toughnesses of human cortical bone were compared to those of bovine cortical bone to test the hypothesis that although human osteonal bone is significantly weaker and more compliant than primary (plexiform) bone, it is not less tough than primary bone. The fracture toughness indices, critical strain energy release rate (G(c)) and critical stress intensity factor (K-c), were determined for human Haversian bone and bovine bone under tension (Mode I) loading using the compact tension method. The effects of thickness, crack growth range and anisotropy on fracture indices for slow stable crack growth in cortical bone were determined. Plane strain assumptions required for application of linear elastic fracture mechanics (LEFM) to bone were investigated. Longitudinal oriented fracture toughness tests were used to assess the crack inhibiting effect of human bone microstructure on frature resistance. Human bone K-c calculated from the stress concentration formula for 2 and 3 mm thick specimens equaled 4.32 and 4.05 MNm(-3/2), respectively. Human bone G(c) calculated from the compliance method equaled 827 Nm(-1) for 2 mm thick specimens and 595 Nm(-1) for 3 mm thick specimens. It was found that crack growth range, thickness and material assumptions affect fracture toughness. K-c calculated from G(c) using an anisotropic relation provided the lowest estimate of K-c and equaled 3.31 MNm(-3/2) for 2 mm thick specimens and 2.81 MN m-(3/2) for 3 mm thick specimens. Both K-c and G(c) were significantly reduced after being adjusted to ASTM standard thickness using ratios determined from bovine bone. The fracture toughness of bovine bone relative to human bone ranged from 1.08 to 1.66. This was compared to the longitudinal strength of bovine bone relative to the longitudinal strength of human bone which is approximately equal to 1.5. We found that even though human bone is significantly weaker than bovine bone, relative to its strength, the toughness of human and bovine bone are roughly similar, but the data were not sufficiently definitive to answer the question of which is tougher.
引用
收藏
页码:309 / 320
页数:12
相关论文
共 47 条
[1]   FRACTURE-TOUGHNESS OF EQUINE METACARPI [J].
ALTO, A ;
POPE, MH .
JOURNAL OF BIOMECHANICS, 1979, 12 (06) :415-421
[2]  
[Anonymous], 1968, FRACTURE
[3]   TENSILE PROPERTIES OF SINGLE OSTEONS [J].
ASCENZI, A ;
BONUCCI, E .
ANATOMICAL RECORD, 1967, 158 (04) :375-&
[4]  
BEARDMORE P, 1980, SCIENCE, V208, P833
[5]   CRACK VELOCITY DEPENDENCE OF LONGITUDINAL FRACTURE IN BONE [J].
BEHIRI, JC ;
BONFIELD, W .
JOURNAL OF MATERIALS SCIENCE, 1980, 15 (07) :1841-1849
[6]   FRACTURE-MECHANICS OF BONE - THE EFFECTS OF DENSITY, SPECIMEN THICKNESS AND CRACK VELOCITY ON LONGITUDINAL FRACTURE [J].
BEHIRI, JC ;
BONFIELD, W .
JOURNAL OF BIOMECHANICS, 1984, 17 (01) :25-34
[7]   ORIENTATION DEPENDENCE OF THE FRACTURE-MECHANICS OF CORTICAL BONE [J].
BEHIRI, JC ;
BONFIELD, W .
JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) :863-&
[8]  
Bonfield W., 1985, BIOMECHANICS CURRENT, P185
[9]  
BONFIELD W, 1978, J BIOMECH, V1, P473
[10]  
Brown Jr W.F., 1966, ASTM SPEC TECH PUBL, V410