EUROPEAN SEMI-ANTHROPOMORPHIC SPINE PHANTOM FOR THE CALIBRATION OF BONE DENSITOMETERS - ASSESSMENT OF PRECISION, STABILITY AND ACCURACY - THE EUROPEAN QUANTITATION OF OSTEOPOROSIS STUDY-GROUP

被引:99
作者
PEARSON, J
DEQUEKER, J
HENLEY, M
BRIGHT, J
REEVE, J
KALENDER, W
LAVALJEANTET, AM
RUEGSEGGER, P
FELSENBERG, D
ADAMS, J
BIRKENHAGER, JC
BRAILLON, P
CURIEL, MD
FISCHER, M
GALAN, F
GEUSENS, P
HYLDSTRUP, L
JAEGER, P
JONSON, R
KALEFEZRAS, J
KOTZKI, P
KROGER, H
VANLINGEN, A
NILSSON, S
OSTEAUX, M
CANO, RP
REID, DM
REINERS, C
RIBOT, C
SCHNEIDER, P
SLOSMAN, DO
WITTENBERG, G
机构
[1] MRC, CLIN RES CTR, HARROW HA1 3UJ, MIDDX, ENGLAND
[2] NORTHWICK PK HOSP & CLIN RES CTR, HARROW HA1 3UJ, MIDDX, ENGLAND
[3] KATHOLIEKE UNIV LEUVEN, ARTHRIT & METAB BONE DIS RES UNIT, PELLENBERG, BELGIUM
[4] SIEMENS MED SYST INC, ERLANGEN, GERMANY
[5] INSERM, U18, PARIS, FRANCE
[6] UNIV ZURICH, ZURICH, SWITZERLAND
[7] ETH ZURICH, INST BIOMED TECH, ZURICH, SWITZERLAND
[8] FREE UNIV BERLIN, KLINIKUM STEGLITZ, W-1000 BERLIN, GERMANY
[9] UNIV MANCHESTER, DEPT DIAGNOST RADIOL, MANCHESTER, LANCS, ENGLAND
[10] UNIV ROTTERDAM HOSP, DEPT MED 3, ROTTERDAM, NETHERLANDS
[11] HOP EDOUARD HERRIOT, CTR ABSORPTIOMETRIKE OSSEUSE, LYON, FRANCE
[12] FDN JIMENEZ DIAZ, E-28040 MADRID, SPAIN
[13] KASSEL STADT KLINIKEN, ZENTRUM RADIOL, KASSEL, GERMANY
[14] HOSP UNIV SEVILLE, DEPT MED, SEVILLE, SPAIN
[15] HVIDOVRE UNIV HOSP, DEPT ENDOCRINOL, HVIDOVRE, DENMARK
[16] UNIV BERN, DEPT DIAGNOST RADIOL, BERN, SWITZERLAND
[17] KLIN FYSIOL AVD NORRA ALVSBORGS LANSSJNKHUS, RADIAT PHYS SECT, TROLLHATTAN, SWEDEN
[18] UNIV IOANNINA, MED PHYS LAB, IOANNINA, GREECE
[19] UNIV KUOPIO, CENT HOSP, DEPT SURG, KUOPIO, FINLAND
[20] UNIV MONTPELLIER, HOP LAPEYRONIE, F-34059 MONTPELLIER, FRANCE
[21] VRIJE UNIV AMSTERDAM, ACAD ZIEKENHUIS, DEPT ENDOCRINOL, AMSTERDAM, NETHERLANDS
[22] UPPSALA UNIV, DEPT DIAGNOST RADIOL, UPPSALA, SWEDEN
[23] FREE UNIV BRUSSELS, AKAD ZIEKENHUIS, DEPT RADIOL, B-1090 BRUSSELS, BELGIUM
[24] UNIV HOSP VIRGEN MACAREN, DEPT MED, SEVILLE, SPAIN
[25] GRAMPIAN AREA HLTH BOARD, GERIATR & SPECIALIST SERV, ABERDEEN, SCOTLAND
[26] UNIV ESSEN GESAMTHSCH KLINIKUM, ZENTRUM RADIOL, W-4300 ESSEN, GERMANY
[27] CHU PURPAN, SERV ENDOCRINOL, UF MALAD OSSEUSES & METAB, TOULOUSE, FRANCE
[28] NUKL MED KLIN & POLIKLIN, WURZBURG, GERMANY
[29] UNIV HOSP GENEVA, DIV CLIN PATHOPHYSIOL, GENEVA, SWITZERLAND
关键词
CROSS-CALIBRATION; DUAL X-RAY ABSORPTIOMETRY (DXA); EUROPEAN SPINE PHANTOM (ESP); OSTEOPOROSIS; QUANTITATIVE COMPUTED TOMOGRAPHY (QCT);
D O I
10.1007/BF02106097
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Up to now it has not been possible to reliably cross-calibrate dual-energy X-ray absorptiometry (DXA) densitometry equipment made by different manufacturers so that a measurement made on an individual subject can be expressed in the units used with a different type of machine. Manufacturers have adopted various procedures for edge detection and calibration, producing various normal ranges which are specific to each individual manufacturer's brand of machine. In this study we have used the recently described European Spine Phantom (ESP, prototype version), which contains three semi-anthropomorphic ''vertebrae'' of different densities made of simulated cortical and trabecular bone, to calibrate a range of DXA densitometers and quantitative computed tomography (QCT) equipment used in the measurement of trabecular bone density of the lumbar vertebrae. Three brands of QCT equipment and three brands of DXA equipment were assessed. Repeat measurements were made to assess machine stability. With the large majority of machines which proved stable, mean values were obtained for the measured low, medium and high density vertebrae respectively. In the case of the QCT equipment these means were for the trabecular bone density, and in the case of the DXA equipment for vertebral body bone density in the posteroanterior projection. All DXA machines overestimated the projected area of the vertebral bodies by incorporating variable amounts of transverse process. In general, the QCT equipment gave measured values which were close to the specified values for trabecular density, but there were substantial differences from the specified values in the results provided by the three DXA brands. For the QCT and Norland DXA machines (posteroanterior view), the relationships between specified densities and observed densities were found to be linear, whereas for the other DXA equipment (posteroanterior view), slightly curvilinear, exponential fits were found to be necessary to fit the plots of observed versus specified densities. From these plots, individual calibration equations were derived for each machine studied. For optimal cross-calibration, it was found to be necessary to use an individual calibration equation for each machine. This study has shown that it is possible to cross-calibrate DXA as well as QCT equipment for the measurement of axial bone density. This will be of considerable benefit for large-scale epidemiological studies as well as for multi-site clinical studies depending on bone densitometry.
引用
收藏
页码:174 / 184
页数:11
相关论文
共 30 条
  • [1] QUANTITATIVE DUAL-ENERGY RADIOGRAPHIC ABSORPTIOMETRY OF THE LUMBAR SPINE - INVIVO COMPARISON WITH DUAL-PHOTON ABSORPTIOMETRY
    BORDERS, J
    KERR, E
    SARTORIS, DJ
    STEIN, JA
    RAMOS, E
    MOSCONA, AA
    RESNICK, D
    [J]. RADIOLOGY, 1989, 170 (01) : 129 - 131
  • [2] CROSS-CALIBRATION OF LIQUID AND SOLID QCT CALIBRATION STANDARDS - CORRECTIONS TO THE UCSF NORMATIVE DATA
    FAULKNER, KG
    GLUER, CC
    GRAMPP, S
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1993, 3 (01) : 36 - 42
  • [3] CROSS-CALIBRATION OF DXA EQUIPMENT - UPGRADING FROM A HOLOGIC QDR 1000/W TO A QDR-2000
    FAULKNER, KG
    GLUER, CC
    ESTILO, M
    GENANT, HK
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (02) : 79 - 84
  • [4] MEASUREMENT OF BONE-MINERAL DENSITY - CURRENT STATUS
    GENANT, HK
    FAULKNER, KG
    GLUER, CC
    [J]. AMERICAN JOURNAL OF MEDICINE, 1991, 91 : S49 - S53
  • [5] GENANT HK, 1994, J BONE MINER RES, V9, P1503
  • [6] QUALITY ASSURANCE FOR BONE DENSITOMETRY RESEARCH STUDIES - CONCEPT AND IMPACT
    GLUER, CC
    FAULKNER, KG
    ESTILO, MJ
    ENGELKE, K
    ROSIN, J
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1993, 3 (05) : 227 - 235
  • [7] A NEW SET OF CALIBRATION STANDARDS FOR ESTIMATING THE FAT AND MINERAL-CONTENT OF VERTEBRAE VIA DUAL ENERGY QCT
    GOODSITT, MM
    JOHNSON, RH
    CHESNUT, CH
    [J]. BONE AND MINERAL, 1991, 13 (03): : 217 - 233
  • [8] HEALEY J, 1992, J BONE MINER RES, V7, pS179
  • [9] HOCHBERG AM, 1988, BONE MINERAL MEASURE, P242
  • [10] MASS ATTENUATION COEFFICIENTS, QUANTITIES AND UNITS FOR USE IN BONE-MINERAL DETERMINATIONS
    JONSON, R
    [J]. OSTEOPOROSIS INTERNATIONAL, 1993, 3 (02) : 103 - 106