ONLINE DETERMINATION OF ACETIC-ACID IN A CONTINUOUS PRODUCTION OF ACETOBACTER-ACETICUS

被引:19
作者
BECKER, T [1 ]
KITTSTEINEREBERLE, R [1 ]
LUCK, T [1 ]
SCHMIDT, HL [1 ]
机构
[1] FRAUNHOFER INST LEBENSMITTELTECHNOL & VERPACKUNG,VERFAHRENSTECH & BIOTECHNOL ABT,MUNICH,GERMANY
关键词
FLOW INJECTION ANALYSIS; FIA; PROCESS CONTROL; IMMOBILIZED ENZYMES; ACETIC ACID;
D O I
10.1016/0168-1656(93)90073-V
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A flow injection system for the determination of acetic acid in the 10-60 mM range was conceived and optimized on basis of the coupled reactions of acetate kinase/pyruvate kinase/lactate dehydrogenase. The enzymes were immobilized in series, a reagent mixture containing PEP, ATP and NADH was pulsed into the analyte stream, and the decrease of the NADH absorption was determined. One injection cycle was performed within 90 s. Two identical parallel enzyme lines were installed, one of them being in use while the other was calibrated. Automated calibration, control of sample dilution, compensation for enzyme activity loss, the switching between the two enzyme lines and the control of all instruments were performed by an appropriate computer system. The analysis of vinegar samples resulted correct and reliable results. The semi-automated control of continuous vinegar production of 60 h yielded very satisfactory results in the range of 0.5-1,5 M after 40-fold dilution and was more reliable than the reference HPLC method. The extension of the analysis system to higher concentrations ranges still demands an optimization of the dilution method. In total, the enzyme-based FIA for continuous acetic acid determination seems to be a very useful and reliable method.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 15 条
[1]  
BANSCH JJ, 1992, THESIS TU MUNCHEN WE
[2]  
BANSCH JJ, 1991, BIOENGINEERING, V3, P26
[3]  
BECKER T, 1993, J CHEM TECHNOL BIOT, V58, P183
[4]  
BELITZ HD, 1987, LEHRBUCH LEBENSMITTE, P796
[5]  
BERGMEYER HU, 1983, METHODS ENYMATIC ANA, V2
[6]  
CAIRO J, 1991, BIOTECHNOL TECH, V5, P389
[7]   NOVEL FLOW-INJECTION ANALYSIS METHOD FOR BIOPROCESS MONITORING [J].
CHUNG, S ;
WEN, XW ;
VILHOLM, K ;
DEBANG, M ;
CHRISTIAN, G ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :77-85
[8]   ONLINE MONITORING AND CONTROL OF FERMENTATION PROCESSES BY FLOW-INJECTION ANALYSIS [J].
FORMAN, LW ;
THOMAS, BD ;
JACOBSON, FS .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :101-111
[9]   EXTENSIVE FLOW-INJECTION DILUTION FOR IN-LINE SAMPLE PRETREATMENT - COMPARISON BETWEEN SINGLE-STAGE AND DUAL-STAGE MODULES [J].
GARN, MB ;
GISIN, M ;
GROSS, H ;
KING, P ;
SCHMIDT, W ;
THOMMEN, C .
ANALYTICA CHIMICA ACTA, 1988, 207 (1-2) :225-231
[10]  
KITTSTEINEREBER.R, 1990, QUANTIFIIERUNG GLYCE, P23