BEHAVIOR OF PLATELETS AND BETA-THROMBOGLOBULIN

被引:9
作者
IVANOVICH, P
HAMMERSCHMIDT, DE
QUINTANILLA, A
KISHIMOTO, T
TANAKA, H
LEVIN, N
KLINKMANN, H
机构
[1] NORTHWESTERN UNIV,SCH MED,CHICAGO,IL 60611
[2] UNIV MINNESOTA,SCH MED,DEPT MED,DIV HEMATOL,MINNEAPOLIS,MN 55455
[3] OSAKA CITY UNIV,SCH MED,DEPT UROL,OSAKA 545,JAPAN
[4] HENRY FORD HOSP,DIV NEPHROL,DETROIT,MI 48202
[5] UNIV ROSTOCK,DEPT INTERNAL MED,O-2500 ROSTOCK,GERMANY
关键词
HEMODIALYSIS; PLATELETS; BETA-THROMBOGLOBULIN; PLATELET AGGREGATION; CUPROPHAN(TM); CUPRAMMONIUM CELLULOSE; CELLULOSE ACETATE; POLYMETHYLMETHACRYLATE; POLYSULFONE; POLYACRYLONITRILE;
D O I
10.1093/ndt/8.supp2.15
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Platelet count, platelet aggregation responses, and plasma beta-thromboglobulin were assessed before and at intervals during each study dialysis. As expected, modest thrombocytopenia was observed following treatment with all dialysers, but Filtral showed the least effect. Concordantly, modest increases in plasma beta-thromboglobulin were observed with all devices except Filtral (caveat: the device also seems to adsorb beta-thromboglobulin). Interpatient variability was more striking for platelet aggregation responses, and made it difficult to discern patterns; however, aggregation in response to ADP was augmented during haemodialysis with the Filtral device, and blunted when the G120 M was employed. Differences between hollow-fibre and parallel plate devices with the same membrane material suggest that membrane geometry, manufacturing residues, membrane support, or potting materials may also contribute to platelet activation.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 24 条
[1]  
ARMITAGE P, 1971, STATISTICAL METHODS, P189
[2]  
BUCCIANTI G, 1982, CLIN NEPHROL, V18, P204
[3]   ANAPHYLATOXIN FORMATION DURING HEMODIALYSIS - COMPARISON OF NEW AND RE-USED DIALYZERS [J].
CHENOWETH, DE ;
CHEUNG, AK ;
WARD, DM ;
HENDERSON, LW .
KIDNEY INTERNATIONAL, 1983, 24 (06) :770-774
[4]   ANAPHYLATOXIN FORMATION DURING HEMODIALYSIS - EFFECTS OF DIFFERENT DIALYZER MEMBRANES [J].
CHENOWETH, DE ;
CHEUNG, AK ;
HENDERSON, LW .
KIDNEY INTERNATIONAL, 1983, 24 (06) :764-769
[5]   COMPLEMENT AND LEUKOCYTE-MEDIATED PULMONARY DYSFUNCTION IN HEMODIALYSIS [J].
CRADDOCK, PR ;
FEHR, J ;
BRIGHAM, KL ;
KRONENBERG, RS ;
JACOB, HS .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (14) :769-774
[6]  
CRADDOCK PR, 1977, J CLIN INVEST, V59, P679
[7]   INVIVO COMPLEMENT ACTIVATION BY POLYANION-POLYCATION COMPLEXES - EVIDENCE THAT C5A IS GENERATED INTRAVASCULARLY DURING HEPARIN-PROTAMINE INTERACTION [J].
FEHR, J ;
ROHR, H .
CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1983, 29 (01) :7-14
[8]   HEMODIALYSIS-ASSOCIATED PLATELET ACTIVATION AND THROMBOCYTOPENIA [J].
HAKIM, RM ;
SCHAFER, AI .
AMERICAN JOURNAL OF MEDICINE, 1985, 78 (04) :575-580
[9]   COMPLEMENT ACTIVATION AND HYPERSENSITIVITY REACTIONS TO DIALYSIS MEMBRANES [J].
HAKIM, RM ;
BREILLATT, J ;
LAZARUS, JM ;
PORT, FK .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (14) :878-882
[10]   BIOCOMPATIBILITY OF DIALYSIS MEMBRANES - EFFECTS OF CHRONIC COMPLEMENT ACTIVATION [J].
HAKIM, RM ;
FEARON, DT ;
LAZARUS, JM .
KIDNEY INTERNATIONAL, 1984, 26 (02) :194-200