NITRIC-OXIDE ADMINISTRATION USING CONSTANT-FLOW VENTILATION

被引:12
作者
SKIMMING, JW
CASSIN, S
BLANCH, PB
机构
[1] UNIV FLORIDA,COLL MED,DEPT PEDIAT,GAINESVILLE,FL 32610
[2] UNIV FLORIDA,COLL MED,DEPT ANESTHESIA,GAINESVILLE,FL 32610
[3] UNIV FLORIDA,COLL MED,RESP CARE SERV,GAINESVILLE,FL 32610
关键词
MECHANICAL VENTILATION; NITRIC OXIDE; PULMONARY; RESPIRATORY; TOXICITY; VASCULATURE;
D O I
10.1378/chest.108.4.1065
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Nitric oxide (NO) gas is known as both a vasodilator and a toxin. It can react with oxygen to form compounds more toxic than itself, such as nitrogen dioxide (NO2), The reactions are time dependent; thus, infusing NO into breathing circuits as close to ventilated subjects as possible may help minimize toxic byproduct exposure. Unfortunately, flow rates commonly used with mechanical ventilation favor laminar gas now (streaming) within the breathing circuits, Streaming could delay mixing of NO with other inhaled gases, This mixing delay may interfere with accurate monitoring and/or delivery of NO, We tested the hypothesis that streaming of NO infused by constant flow into the inspiratory limb of a constant-flow mechanical ventilation system can lead to NO concentration delivery estimate errors. We then compared the NO2 concentrations at the ventilator Y-piece with three different NO mixing methods: blending the gases before they reach the breathing circuit inspiratory limb, infusing NO directly into the breathing circuit inspiratory limb far enough from the Y-piece to ensure thorough mixing and infusing NO directly into the breathing circuit inspiratory limb immediately before the gases reach an in-line mixing device placed close to the Y-piece, Our results indicate that streaming can lead to NO concentration delivery estimate errors and that these errors can be characterized by measuring NO concentration variations across the inspiratory tubing's luminal diameter, NO2 concentrations measured at the ventilator Y-piece were dependent on NO concentrations (p<0.0001), NO delivery methods (p<0.0001), and interactions between NO concentrations and NO delivery methods (p<0.0001). We conclude that gas streaming and toxic byproduct exposure should be considered together when choosing an NO delivery method.
引用
收藏
页码:1065 / 1072
页数:8
相关论文
共 46 条
[1]  
ABMAN SH, 1993, PEDIATRICS, V92, P606
[2]  
ARANYI C, 1976, ENVIRON HEALTH PERSP, V16, P180
[4]   PULMONARY NO2 TOXICITY IN NEONATE AND ADULT GUINEA-PIGS AND RATS [J].
AZOULAYDUPUIS, E ;
TORRES, M ;
SOLER, P ;
MOREAU, J .
ENVIRONMENTAL RESEARCH, 1983, 30 (02) :322-339
[5]   APPARENT HYDROXYL RADICAL PRODUCTION BY PEROXYNITRITE - IMPLICATIONS FOR ENDOTHELIAL INJURY FROM NITRIC-OXIDE AND SUPEROXIDE [J].
BECKMAN, JS ;
BECKMAN, TW ;
CHEN, J ;
MARSHALL, PA ;
FREEMAN, BA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (04) :1620-1624
[6]   EFFECTS OF NO2 ON LUNGS OF AGING RATS .1. MORPHOLOGY [J].
CABRALANDERSON, LJ ;
EVANS, MJ ;
FREEMAN, G .
EXPERIMENTAL AND MOLECULAR PATHOLOGY, 1977, 27 (03) :353-365
[7]   INHALED NITRIC-OXIDE REVERSES HYPOXIC PULMONARY VASOCONSTRICTION IN DOGS - A PRACTICAL NITRIC-OXIDE DELIVERY AND MONITORING-SYSTEM [J].
CHANNICK, RN ;
NEWHART, JW ;
JOHNSON, FW ;
MOSER, KM .
CHEST, 1994, 105 (06) :1842-1847
[9]   TIME-DOSE RESPONSE FOR NITROGEN-DIOXIDE EXPOSURE IN AN INFECTIVITY MODEL SYSTEM [J].
COFFIN, DL ;
GARDNER, DE ;
BLOMMER, EJ .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1976, 13 (FEB) :11-15
[10]   ROLE OF TIME AS A FACTOR IN TOXICITY OF CHEMICAL COMPOUNDS IN INTERMITTENT AND CONTINUOUS EXPOSURES .2. EFFECTS OF INTERMITTENT EXPOSURE [J].
COFFIN, DL ;
GARDNER, DE ;
SIDORENKO, GI ;
PINIGIN, MA .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1977, 3 (5-6) :821-828