Development of reproducible test inocula for disinfectant testing

被引:12
作者
Bloomfield, SF
Arthur, M
Gibson, H
Morley, K
Gilbert, P
Brown, MRW
机构
[1] CAMPDEN & CHORLEYWOOD FOOD RES ASSOC,CHIPPING CAMPDEN,GLOS,ENGLAND
[2] UNIV MANCHESTER,DEPT PHARM,MANCHESTER M13 9PL,LANCS,ENGLAND
[3] UNIV ASTON,DEPT PHARMACEUT & BIOL SCI,BIRMINGHAM B4 7ET,W MIDLANDS,ENGLAND
关键词
D O I
10.1016/0964-8305(95)00100-X
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
For the development and approval of disinfectants, laboratory tests which combine repeatability and reproducibility with relevance to practical conditions are required to ensure optimum standards of efficacy under use conditions. Over the years, although an increasingly rigorous approach has been adopted in devising European and US Standard Test Methods for disinfectants, which includes specifying all aspects of test methodology, the precision of these methods remains a matter for concern. Studies of proposed European test methods indicate that, although some of the variability is methodological in origin, or is derived from errors in preparing test solutions and performing the tests, one of the major sources of error is lack of reproducibility in the performance of the test inoculum. Results indicate that day to day variability in biocide sensitivity of sequential subcultures arises not only from variations in the phenotype generated fr om the laboratory stock culture, but also from lack of standardization of conditions used to harvest and prepare test inocula. Further reductions in reproducibility between test periods both within or between laboratories probably arise from alterations in the genotype of the laboratory stock culture or source culture during storage under conditions of refrigeration, freezing or freeze-drying. Methods for production of reproducible inocula are considered and some studies aimed at development of test inocula with more reproducible biocide resistance are described. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:311 / 331
页数:21
相关论文
共 29 条
  • [1] Adams GDJ, 1995, MICROBIOLOGICAL QUAL, P89
  • [2] A NOTE ON INOCULUM REPRODUCIBILITY - A COMPARISON BETWEEN SOLID AND LIQUID CULTURE
    ALHITI, MMA
    GILBERT, P
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1983, 55 (01): : 173 - 175
  • [3] EVALUATION OF THE REPEATABILITY AND REPRODUCIBILITY OF EUROPEAN SUSPENSION TEST METHODS FOR ANTIMICROBIAL ACTIVITY OF DISINFECTANTS AND ANTISEPTICS
    BLOOMFIELD, SF
    LOONEY, E
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1992, 73 (01): : 87 - 93
  • [4] COMPARATIVE TESTING OF DISINFECTANT AND ANTISEPTIC PRODUCTS USING PROPOSED EUROPEAN SUSPENSION TESTING METHODS
    BLOOMFIELD, SF
    ARTHUR, M
    LOONEY, E
    BEGUN, K
    PATEL, H
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 1991, 13 (05) : 233 - 237
  • [5] BLOOMFIELD SF, 1995, MICROBIOLOGICAL QUAL, P189
  • [6] *BRIT STAND I, 1987, 6905 BS BRIT STAND I
  • [7] *BRIT STAND I, 1994, 1275 PREN BRIT STAND
  • [8] *BRIT STAND I, 1993, 1040 PREN BRIT STAND
  • [9] *BRIT STAND I, 1985, 541 BRIT STAND I
  • [10] *BRIT STAND I, 1994, 1656 PREN BRIT STAND