SIMULTANEOUS-FLUORIMETRIC METHODS FOR THE DETERMINATION OF AMMONIA AND UREA BY USE OF FLOW-INJECTION CONFIGURATIONS WITH DUAL INJECTION VALVES

被引:12
作者
IZQUIERDO, A [1 ]
LINARES, P [1 ]
DECASTRO, MDL [1 ]
VALCARCEL, M [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,CORDOBA,SPAIN
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1990年 / 336卷 / 06期
关键词
D O I
10.1007/BF00323120
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two fluorimetric methods are proposed for the simultaneous determination of ammonia and urea based on the reaction of the former with o-phthalaldehyde/2-mercaptoethanol and on the use of a dual injection system in which the valves are coupled in series or in parallel. An enzymatic reactor converts urea into ammonia which is determined by the same reaction. These configurations provide very similar results with a linear determination range between 0.5 and 10.0 μg ml-1 and a sampling frequency of 60 h-1. The proposed methods are very tolerant to foreign species commonly found in water, as shown by applying them to samples of different origins. © 1990 Springer-Verlag.
引用
收藏
页码:490 / 493
页数:4
相关论文
共 15 条
[1]   APPLICATIONS OF FLOW-INJECTION ANALYSIS IN A POWER-PLANT DETERMINATION OF PH, AMMONIA AND HYDRAZINE IN AN AVT-CONDITIONED WATER STEAM CYCLE [J].
BALCONI, ML ;
SIGON, F ;
FERRAROLI, R ;
REALINI, F .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :367-374
[2]   DETERMINATION OF PH, CONDUCTIVITY, RESIDUAL CHLORINE AND AMMONIUM AND NITRITE IONS IN WATER WITH AN UNSEGMENTED FLOW CONFIGURATION [J].
CANETE, F ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYST, 1988, 113 (05) :739-742
[3]   SIMULTANEOUS DETERMINATION OF AMMONIA AND UREA WITH AN ASYMMETRIC MERGING ZONES FLOW-INJECTION CONFIGURATION [J].
COSANO, JS ;
CALLE, JL ;
PINILLOS, JL ;
LINARES, P ;
DECASTRO, MDL .
ANALYTICA CHIMICA ACTA, 1989, 221 (01) :173-177
[4]  
DECASTRO MDL, 1986, TRAC-TREND ANAL CHEM, V5, P71
[5]  
FOGG AG, 1984, ANALYST, V109, P901, DOI 10.1039/an9840900901
[6]   FLOW-INJECTION ANALYSIS FOR GLUCOSE AND UREA WITH ENZYME REACTORS AND ONLINE DIALYSIS [J].
GORTON, L ;
OGREN, L .
ANALYTICA CHIMICA ACTA, 1981, 130 (01) :45-53
[7]  
HAN W, 1986, CHINESE J ANAL CHEM, V14, P387
[8]   FLOW-INJECTION ANALYSIS BY USING ACID-BASE OR METAL-LIGAND BUFFERS AND COLOR-INDICATORS [J].
ISHIBASHI, N ;
IMATO, T .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (03) :244-248
[9]   DETERMINATION OF CREATININE IN UNDILUTED BLOOD-SERUM BY ENZYMATIC FLOW-INJECTION ANALYSIS WITH OPTOSENSING [J].
JEPPESEN, MT ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :147-159
[10]  
JONES EA, 1985, MINTEK M200 REP