CHEMOMETRICS AND SPECTRAL FREQUENCY SELECTION

被引:34
作者
BROWN, PJ [1 ]
SPIEGELMAN, CH [1 ]
DENHAM, MC [1 ]
机构
[1] TEXAS A&M UNIV SYST,DEPT STAT,COLLEGE STN,TX 77843
来源
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES | 1991年 / 337卷 / 1647期
关键词
D O I
10.1098/rsta.1991.0127
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In many fields of science, the simple straight line has received more attention as a basis for calibration than any other form. This is because measuring devices have been mainly univariate and have had calibration curves which were sufficiently linear. As scientific fields become more computationally intensive they rely on more computer-driven multivariate measurement devices. The number of responses may be large. For example modern scanning infrared (IR) spectroscopes measure the absorptions or reflectances at a sequence of around one thousand frequencies. Training data may consist of the order of 10 to 100 carefully designed samples for which the true composition is either known by formulation or accurately determined by wet chemistry. In future one wishes to predict the true composition from the spectrum. In this paper we develop a variable selection approach which is both simple in concept and computationally easy to implement. Its motivation is the minimization of the width of a confidence interval. The technique for data reduction is illustrated on a mid-IR spectroscopic analysis of a liquid detergent in which the calibrating data consists of 12 observations of absorptions at 1168 frequency channels (responses) corresponding to five chemical ingredients.
引用
收藏
页码:311 / 322
页数:12
相关论文
共 26 条
  • [1] Berry D.A., 1988, BAYESIAN STATISTICS, P79
  • [2] MEAN SQUARED ERROR AND SELECTION IN MULTIVARIATE CALIBRATION
    BROWN, PJ
    SPIEGELMAN, CH
    [J]. STATISTICS & PROBABILITY LETTERS, 1991, 12 (02) : 157 - 159
  • [3] BROWN PJ, 1982, J R STAT SOC B, V44, P287
  • [4] BROWN PJ, 1987, J ROY STAT SOC B MET, V49, P46
  • [5] BROWN PJ, 1990, ANAL P, V27, P303
  • [6] BROWN PJ, 1992, IN PRESS BAYESIAN ST, V4
  • [7] BROWN PJ, 1991, VARIABLE SELECTION M
  • [8] THE EFFECT OF IGNORING SMALL MEASUREMENT ERRORS IN PRECISION INSTRUMENT CALIBRATION
    CARROLL, RJ
    SPIEGELMAN, CH
    [J]. JOURNAL OF QUALITY TECHNOLOGY, 1986, 18 (03) : 170 - 173
  • [9] A QUICK AND EASY MULTIPLE-USE CALIBRATION-CURVE PROCEDURE
    CARROLL, RJ
    SPIEGELMAN, CH
    SACKS, J
    [J]. TECHNOMETRICS, 1988, 30 (02) : 137 - 141
  • [10] Cross A.D., 1969, INTRO PRACTICAL INFR