QUANTITATIVE-ANALYSIS OF MITOTIC AND EARLY-G1 CELLS USING MONOCLONAL-ANTIBODIES AGAINST THE AF-2-PROTEIN

被引:13
作者
DIVINCI, A [1 ]
GEIDO, E [1 ]
PFEFFER, U [1 ]
VIDALI, G [1 ]
GIARETTI, W [1 ]
机构
[1] NATL INST CANC RES IST,BIOPHYS CYTOMETRY LAB,VIALE BENEDETTO 15,N10,I-16132 GENOA,ITALY
来源
CYTOMETRY | 1993年 / 14卷 / 04期
关键词
MITOSIS; PROLIFERATION ASSOCIATED ANTIGEN; FLOW CYTOMETRY;
D O I
10.1002/cyto.990140411
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have recently described a novel protein (AF-2), conserved between fission yeast and man, and we have shown by flow cytometry (FCM) that AF-2 is highly accessible to specific monoclonal antibodies (MoAbs) in mitotic and postmitotic early-G1 phase cells. The aim of the present study was to optimize the FCM methodology using MoAbs against AF-2 and to show that the evaluation of the mitotic cells, using different cell lines, was quantitative and reproducible. We found that a method based on fixation with ethanol, instead of formalin, resulted in improved DNA histogram coefficients of variation and implemented separation of early-G1 cells from late-G1 cells. In addition, by eliminating several cell permeabilization and protein salt extraction steps, the method became straightforward, conserved a clear-cut separation of the green fluorescence of M- with respect to G2-phase cells, and did not significantly affect cellular integrity. The coefficient of correlation among the mitotic index values evaluated by this FCM method using MoAbs against AF-2 and by microscopic visual counting was R = 0.94. When the FCM/AF-2 method was tested against an independent FCM method, which allows clear separation of M- and G2-phase cells according to 90-degrees scattering, we found R = 0.93. We conclude that MoAbs against the AF-2 protein may be used in FCM for quantitative analysis and for isolation of M-phase cells, providing as well, the identification of the early-G1 cell subcompartment. The method may, in addition, be useful for the simultaneous detection of cytoplasmic cytokeratin and nuclear AF-2 antigen.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 15 条
  • [1] BAAK JPA, 1985, CANCER, V56, P374, DOI 10.1002/1097-0142(19850715)56:2<374::AID-CNCR2820560229>3.0.CO
  • [2] 2-9
  • [3] QUANTITATIVE-ANALYSIS OF A NUCLEAR ANTIGEN IN INTERPHASE AND MITOTIC CELLS
    CLEVENGER, CV
    EPSTEIN, AL
    BAUER, KD
    [J]. CYTOMETRY, 1987, 8 (03): : 280 - 286
  • [4] INSITU FACTORS AFFECTING STABILITY OF THE DNA HELIX IN INTERPHASE NUCLEI AND METAPHASE CHROMOSOMES
    DARZYNKIEWICZ, Z
    TRAGANOS, F
    CARTER, SP
    HIGGINS, PJ
    [J]. EXPERIMENTAL CELL RESEARCH, 1987, 172 (01) : 168 - 179
  • [5] SUBPOPULATION ANALYSIS OF DRUG-INDUCED CELL-CYCLE DELAY IN HUMAN-TUMOR CELLS USING 90-DEGREES LIGHT SCATTER
    EPSTEIN, RJ
    WATSON, JV
    SMITH, PJ
    [J]. CYTOMETRY, 1988, 9 (04): : 349 - 358
  • [6] Geido E, 1990, Methods Cell Biol, V33, P149
  • [7] A NEW METHOD TO DISCRIMINATE G1-POSTMITOTIC, S-POSTMITOTIC, G2-POSTMITOTIC, M-POSTMITOTIC AND G1-POSTMITOTIC CELLS
    GIARETTI, W
    NUSSE, M
    BRUNO, S
    DIVINCI, A
    GEIDO, E
    [J]. EXPERIMENTAL CELL RESEARCH, 1989, 182 (01) : 290 - 295
  • [8] FLOW CYTOMETRIC DISCRIMINATION OF MITOTIC CELLS - RESOLUTION OF M-PHASE, AS WELL AS G1-PHASE, S-PHASE, AND G2-PHASE NUCLEI WITH MITHRAMYCIN, PROPIDIUM IODIDE, AND ETHIDIUM-BROMIDE AFTER FIXATION WITH FORMALDEHYDE
    LARSEN, JK
    MUNCHPETERSEN, B
    CHRISTIANSEN, J
    JORGENSEN, K
    [J]. CYTOMETRY, 1986, 7 (01): : 54 - 63
  • [9] LIPPONEN PK, 1992, INT J ONCOL, V1, P387
  • [10] FLOW CYTOMETRIC DETECTION OF MITOTIC CELLS USING THE BROMODEOXYURIDINE DNA TECHNIQUE IN COMBINATION WITH 90-DEGREES AND FORWARD SCATTER MEASUREMENTS
    NUSSE, M
    JULCH, M
    GEIDO, E
    BRUNO, S
    DIVINCI, A
    GIARETTI, W
    RUOSS, K
    [J]. CYTOMETRY, 1989, 10 (03): : 312 - 319