A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC PROCEDURE FOR THE SEPARATION OF COCAINE AND SOME OF ITS METABOLITES FROM ACEPROMAZINE, KETAMINE, AND ATROPINE FROM SERUM

被引:8
作者
MUZTAR, J
CHARI, G
BHAT, R
RAMARAO, S
VIDYASAGAR, D
机构
[1] Department of Pediatrics, The University of Illinois at Chicago, Chicago, Illinois
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1995年 / 18卷 / 13期
基金
美国国家卫生研究院;
关键词
D O I
10.1080/10826079508009314
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatographic procedure for the separation of cocaine and its metabolites from such non-test drugs as acepromazine, ketamine and atropine in serum is described. The method involves the use of a SemiPermeable Surface (SPS) C8 column with a mobile phase constituted of 3.25% tetrahydrofuran and 96.75% 0.0025 M potassium phosphate buffer, v/v, containing 0.0025% triethylamine, the final pH of the mobile phase being 2.75. The flow rate was 0.5 ml/min. A photodiode array detector equipped with a computer software was used to monitor the analyte peaks. Retention times for cocaine (COG), benzoylecgonine (BE), benzoylnorecgonine (BN), norcocaine (NOR) and bupivacaine (BV) were 15.5, 7.4, 12.25, 21.0 and 24 minutes, respectively. The non-test drugs ketamine and atropine co-eluted at 10.0 minutes while acepromazine eluted with the solvent front (3.8 min.). The sensitivity of this assay for each of COC, BE, BN and NOR, at a signal to noise (S/N) ratio of greater than 6.0, was 1.0 ng/ml while that for BV was 5ng/ml at the same S/N value.
引用
收藏
页码:2635 / 2645
页数:11
相关论文
共 16 条
  • [1] BINIENDA Z, 1993, DRUG METAB DISPOS, V21, P364
  • [2] BROWNE SP, 1991, J FORENSIC SCI, V36, P1662
  • [3] HOWELL LL, 1991, J PHARMACOL EXP THER, V258, P178
  • [4] JATLOW P, 1990, CLIN CHEM, V36, P1436
  • [5] DETERMINATION OF COCAINE AND SELECTED METABOLITES IN CANINE AND HUMAN-SERUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON COUPLED CYANOPROPYL AND SILICA COLUMNS
    LAMPERT, BM
    STEWART, JT
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 495 : 153 - 165
  • [6] SIMULTANEOUS DETERMINATION OF COCAINE AND ITS METABOLITES WITH CAFFEINE IN RAT SERUM MICROSAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LAU, CE
    MA, F
    FALK, JL
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 532 (01): : 95 - 103
  • [7] LITTLE BB, 1989, OBSTET GYNECOL, V73, P157
  • [8] DETERMINATION OF THE ENANTIOMERIC COMPOSITION OF SAMPLES OF COCAINE BY NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH UV DETECTION
    MACGREGOR, RR
    FOWLER, JS
    WOLF, AP
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 590 (02): : 354 - 358
  • [9] DETERMINATION OF COCAINE, BENZOYLECGONINE AND ECGONINE METHYL-ESTER IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MILLER, RL
    DEVANE, CL
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (02): : 412 - 418
  • [10] EFFECT OF INTRAVENOUS COCAINE ON UTERINE BLOOD-FLOW IN THE GRAVID BABOON
    MORGAN, MA
    SILAVIN, SL
    RANDOLPH, M
    PAYNE, GG
    SHELDON, RE
    FISHBURNE, JI
    WENTWORTH, RA
    NATHANIELSZ, PW
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1991, 164 (04) : 1021 - 1030