DETERMINATION OF RARE-EARTH IMPURITIES IN ULTRAPURE EUROPIUM OXIDE BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:31
作者
ZHANG, SX
MURACHI, S
IMASAKA, T
WATANABE, M
机构
[1] KYUSHU UNIV,FAC ENGN,FUKUOKA 812,JAPAN
[2] DAIDEN CO LTD,DEPT RES & DEV,KURUME,FUKUOKA 830,JAPAN
[3] KYUSHU UNIV,CTR ADV INSTRUMENT ANAL,FUKUOKA 812,JAPAN
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; RARE EARTH ELEMENTS; EUROPIUM OXIDE; SPACE CHARGE EFFECT;
D O I
10.1016/0003-2670(95)00273-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trace quantities of rare earth elements (REEs) in ultrapure europium oxide (Eu2O3) are measured by inductively coupled plasma mass spectrometry (ICP-MS). The signal intensity of REE decreases with increasing concentration of europium oxide. Then, the internal standard method is examined to minimize this signal suppression. Four internal standards, cadmium (Cd-111(+)) and indium (In-115(+)), and thallium ((TI+)-T-205) and bismuth (Bi-209(+)) are investigated, since their mass numbers are close to those of lighter (Y-89(+)-Gd-157(+)) and heavier (Tb-159(+)-Lu-175(+)) REEs, respectively. The use of internal standards of Cd and In suppress interference for lighter REEs, and Tl and Bi for heavier REEs. These results imply the interference concerned with a mass-related space charge effect. In trace analysis of REE impurities in ultrapure Eu2O3, In and TL are suggested to be used as internal standards for lighter and heavier REEs, respectively, due to the recoveries close to 100%. Lighter REE oxide ions occurring in a plasma generally interfere with the determination of heavier REEs. However, almost all REEs are determined correctly even at ultratrace levels by a proper selection of isotope. Unfortunately, polyatomic ions from the europium oxide such as (EuO+)-Eu-153 and (EuOH+)-Eu-153-O-18 ions seriously interfere with the determination of Tm-169(+) and Yb-172(+). These interferences are reduced by using ion chromatography (IC) combined with ICP-MS detection.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 19 条
[1]   DETERMINATION OF ULTRATRACE NEODYMIUM IN HIGH-PURITY LANTHANUM COMPOUNDS BY HIGH-ACCURACY ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC ANALYSIS WITH CHEMICAL PRECONCENTRATION [J].
BEARY, ES ;
PAULSEN, PJ .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :431-439
[2]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[3]   DETERMINATION OF RARE-EARTH ELEMENTS BY LIQUID-CHROMATOGRAPHIC SEPARATION USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION [J].
BRAVERMAN, DS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (01) :43-46
[5]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474
[7]  
JARVIS KE, 1992, HDB INDUCTIVELY COUP, P35
[8]   DETERMINATION OF RARE-EARTH ELEMENTS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ION CHROMATOGRAPHY [J].
KAWABATA, K ;
KISHI, Y ;
KAWAGUCHI, O ;
WATANABE, Y ;
INOUE, Y .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2137-2140
[9]   MULTIVARIATE CALIBRATION IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
KETTERER, ME ;
RESCHL, JJ ;
PETERS, MJ .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2031-2040
[10]   EFFECTS OF OPERATING-CONDITIONS ON THE DETERMINATION OF THE RARE-EARTH ELEMENTS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
LONGERICH, HP ;
FRYER, BJ ;
STRONG, DF ;
KANTIPULY, CJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :75-92