THERMAL-CONDUCTIVITY OF R134A

被引:42
作者
LAESECKE, A [1 ]
PERKINS, RA [1 ]
DECASTRO, CAN [1 ]
机构
[1] UNIV LISBON,FAC CIENCIAS,DEPT QUIM,P-1700 LISBON,PORTUGAL
关键词
LIQUID; R134A; SUPERCRITICAL FLUID; 1,1,1,2-TETRAFLUOROETHANE; THERMAL CONDUCTIVITY; TRANSIENT HOT WIRE INSTRUMENT; VAPOR;
D O I
10.1016/0378-3812(92)87073-V
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal conductivity measurements are reported for the alternative refrigerant 1,1,1,2-tetrafluoroethane (R134a). These measurements were made over the temperature range from 200 to 390 K at pressures to 70 MPa. Data are reported for the liquid, vapor, and supercritical fluid phases. A significant critical enhancement is observed for R134a. A thermal conductivity surface, which fits our data to +/-3.8% at 95% confidence, is provided for R134a. Correlations are also provided for the saturated vapor and saturated liquid thermal conductivity of R134a. Comparisons are made with other available thermal conductivity data for the dilute gas, saturated vapor, and saturated liquid.
引用
收藏
页码:263 / 274
页数:12
相关论文
共 16 条
[1]   THERMAL-CONDUCTIVITY OF CHLOROBENZENE AT PRESSURES UP TO 430-MPA [J].
DECASTRO, CAN ;
DIX, M ;
FARELEIRA, JMN ;
LI, SFY ;
WAKEHAM, WA .
PHYSICA A, 1989, 156 (01) :534-546
[2]   MODEL-CALCULATIONS OF THE RELATIVE EFFECTS OF CFCS AND THEIR REPLACEMENTS ON STRATOSPHERIC OZONE [J].
FISHER, DA ;
HALES, CH ;
FILKIN, DL ;
KO, MKW ;
SZE, ND ;
CONNELL, PS ;
WUEBBLES, DJ ;
ISAKSEN, ISA ;
STORDAL, F .
NATURE, 1990, 344 (6266) :508-512
[3]   MODEL-CALCULATIONS OF THE RELATIVE EFFECTS OF CFCS AND THEIR REPLACEMENTS ON GLOBAL WARMING [J].
FISHER, DA ;
HALES, CH ;
WANG, WC ;
KO, MKW ;
SZE, ND .
NATURE, 1990, 344 (6266) :513-516
[4]  
HUBER ML, 1991, UNPUB FLUID PHASE EQ
[5]  
HUBER ML, 1991, UNPUB INT J REFRIG
[6]   CROSSOVER FROM SINGULAR TO REGULAR BEHAVIOR OF THE TRANSPORT-PROPERTIES OF FLUIDS IN THE CRITICAL REGION [J].
OLCHOWY, GA ;
SENGERS, JV .
PHYSICAL REVIEW LETTERS, 1988, 61 (01) :15-18
[7]   A HIGH-TEMPERATURE TRANSIENT HOT-WIRE THERMAL-CONDUCTIVITY APPARATUS FOR FLUIDS [J].
PERKINS, RA ;
RODER, HM ;
DECASTRO, CAN .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1991, 96 (03) :247-269
[8]   COMPARISON OF THE REFRIGERANTS HFC-134A AND CFC-12 [J].
PETERSSON, B ;
THORSELL, H .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1990, 13 (03) :176-180
[9]   STRATOSPHERIC OZONE DEPLETION AND FUTURE LEVELS OF ATMOSPHERIC CHLORINE AND BROMINE [J].
PRATHER, MJ ;
WATSON, RT .
NATURE, 1990, 344 (6268) :729-734
[10]   A TRANSIENT HOT-WIRE THERMAL-CONDUCTIVITY APPARATUS FOR FLUIDS [J].
RODER, HM .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1981, 86 (05) :457-493