FILTER WHEEL EQUALIZATION FOR CHEST RADIOGRAPHY - A COMPUTER-SIMULATION

被引:9
作者
BOONE, JM [1 ]
DURYEA, J [1 ]
STEINER, RM [1 ]
机构
[1] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,DEPT RADIOL,PHILADELPHIA,PA 19107
关键词
CHEST RADIOGRAPHY; RADIOGRAPHIC EQUALIZATION; COMPUTER SIMULATION; FILTER WHEEL;
D O I
10.1118/1.597510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A chest radiographic equalization system using lung-shaped templates mounted on filter wheels is under development. Using this technique, 25 lung templates for each lung are available on two computer controlled wheels which are located in close proximity to the x-ray tube. The large magnification factor (>10X) of the templates assures low-frequency equalization due to the blurring of the focal spot. A low-dose image is acquired without templates using a (generic) digital receptor, the image is analyzed, and the left and right lung fields are automatically identified using software developed for this purpose. The most appropriate left and right lung templates are independently selected and are positioned into the field of view at the proper location under computer control. Once the templates are positioned, acquisition of the equalized radiographic image onto film commences at clinical exposure levels. The templates reduce the exposure to the lung fields by. attenuating a fraction of the incident x-ray fluence so that the exposure to the mediastinum and diaphragm areas can be increased without overexposing the lungs. A data base of 824 digitized chest radiographs was used to determine the shape of the specific lung templates, for both left and right lung fields. A second independent data base of 208 images was used to test the performance of the templates using computer simulations. The template shape characteristics derived from the clinical image data base are demonstrated. The detected exposure in the lung fields on conventional chest radiographs was found to be, on average, three times the detected exposure behind the diaphragm and mediastinum. The simulated filter wheel equalization technique yielded detected exposure levels that were approximately equal in both the lung fields and the rest of the image. In addition to illustrating that the filter-wheel equalization technique may be feasible for chest radiography, the simulations also provided important information for the mechanical construction of a filter wheel equalization system.
引用
收藏
页码:1029 / 1037
页数:9
相关论文
共 13 条
[1]  
ANTONUK LE, 1992, MED PHYS, V20, P1455
[2]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]   A FULLY AUTOMATED ALGORITHM FOR THE SEGMENTATION OF LUNG FIELDS ON DIGITAL CHEST RADIOGRAPHIC IMAGES [J].
DURYEA, J ;
BOONE, JM .
MEDICAL PHYSICS, 1995, 22 (02) :183-191
[4]   PRIMARY X-RAY DODGING [J].
EDHOLM, PR ;
JACOBSON, B .
RADIOLOGY, 1971, 99 (03) :694-&
[5]  
FUCHS AW, 1934, MED RADIOGR CLIN PHO, V10, P9
[6]   DIGITAL BEAM ATTENUATOR TECHNIQUE FOR COMPENSATED CHEST RADIOGRAPHY [J].
HASEGAWA, BH ;
NAIMUDDIN, S ;
DOBBINS, JT ;
MISTRETTA, CA ;
PEPPLER, WW ;
HANGIANDREOU, NJ ;
CUSMA, JT ;
MCDERMOTT, JC ;
KUDVA, BV ;
MELBYE, KM .
RADIOLOGY, 1986, 159 (02) :537-543
[8]   A SCANNING SYSTEM FOR CHEST RADIOGRAPHY WITH REGIONAL EXPOSURE CONTROL - PRACTICAL IMPLEMENTATION [J].
PLEWES, DB ;
VOGELSTEIN, E .
MEDICAL PHYSICS, 1983, 10 (05) :655-663
[9]   X-RAY-IMAGING USING AMORPHOUS SELENIUM - DETERMINATION OF X-RAY-SENSITIVITY BY PULSE-HEIGHT SPECTROSCOPY [J].
ROWLANDS, JA ;
DECRESCENZO, G ;
ARAJ, N .
MEDICAL PHYSICS, 1992, 19 (04) :1065-1069
[10]   AMBER - A SCANNING MULTIPLE-BEAM EQUALIZATION SYSTEM FOR CHEST RADIOGRAPHY [J].
VLASBLOEM, H ;
KOOL, LJS .
RADIOLOGY, 1988, 169 (01) :29-34