DETERMINATION OF TRACE LEVELS OF COPPER(II), ALUMINUM(III) AND IRON(III) BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A NOVEL ONLINE SAMPLE PRECONCENTRATION TECHNIQUE

被引:39
作者
RYAN, E [1 ]
MEANEY, M [1 ]
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
COLUMN SWITCHING; 8-HYDROXYQUINOLINE; CHELATION; COPPER; ALUMINUM AND IRON;
D O I
10.1039/an9921701435
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A column switching high-performance liquid chromatographic technique for the determination of copper(II), aluminium(III) and iron(III) as their 8-hydroxyquinolinate complexes using spectrophotometric detection at 400 nm is described. On-line preconcentration of the metal chelates was effected using a 10 x 1.5 mm i.d. pre-column packed with C18 reversed-phase sorbent. The pre-column was mounted before the analytical column; by manual actuation of a six-port switching valve it could be switched on-line. The metal chelates were resolved by reversed-phase high-performance liquid chromatography on the analytical column following elution from the pre-column with the appropriate mobile phase. A systematic approach to this type of trace enrichment is outlined, and the results show an increase in both sensitivity and selectivity over previous methods. The linear dynamic range is from 5 ppb to 10 ppm for Al(III) and from 40 ppb to 5 ppm for both Cu(II) and Fe(III). Application of the technique to waste water from a mine and to beverage samples is reported.
引用
收藏
页码:1435 / 1439
页数:5
相关论文
共 18 条
[1]   MONITORING OF VETERINARY DRUG RESIDUES BY A COMBINATION OF CONTINUOUS-FLOW TECHNIQUES AND COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. SULFONAMIDES IN EGG, MEAT AND MILK USING POST-COLUMN DERIVATIZATION WITH DIMETHYLAMINOBENZALDEHYDE [J].
AERTS, MML ;
BEEK, WMJ ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1988, 435 (01) :97-112
[3]  
BRINKMAN U A T, 1990, Analytical Proceedings, V27, P114
[4]   WATER-SOLUBLE QUINOLIN-8-OL POLYMER FOR LIQUID-PHASE SEPARATION OF ELEMENTS [J].
GECKELER, KE ;
BAYER, E ;
VOROBEVA, GA ;
SPIVAKOV, BY .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :171-174
[5]   ANALYSIS OF BROMACIL, DIURON AND 3,4-DICHLOROANILINE IN CONTAMINATED WELL WATER, USING A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMN-SWITCHING PROCEDURE [J].
GOEWIE, CE ;
HOGENDOORN, EA .
JOURNAL OF CHROMATOGRAPHY, 1987, 410 (01) :211-216
[6]   STUDIES ON SAMPLE PRECONCENTRATION IN ION CHROMATOGRAPHY .2. AN AUTOMATED, SINGLE PUMP PRECONCENTRATION SYSTEM FOR NON-SUPPRESSED ION CHROMATOGRAPHY WITH CONDUCTIVITY DETECTION [J].
HECKENBERG, AL ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1985, 330 (01) :95-111
[7]  
IRVING H, 1961, TREATISE ANAL CHEM 1, V3
[8]   SELECTIVE CONCENTRATION OF COBALT IN SEAWATER BY COMPLEXATION WITH VARIOUS LIGANDS AND SORPTION ON MACROPOROUS RESINS [J].
ISSHIKI, K ;
NAKAYAMA, E .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :291-295
[9]   PRECONCENTRATION OF TRACE-METALS FROM SEAWATER WITH 7-DODECENYL-8-QUINOLINOL IMPREGNATED MACROPOROUS RESIN [J].
ISSHIKI, K ;
TSUJI, F ;
KUWAMOTO, T ;
NAKAYAMA, E .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2491-2495
[10]   AUTOMATED ONLINE ION-EXCHANGE TRACE ENRICHMENT SYSTEM WITH FLAME ATOMIC-ABSORPTION DETECTION [J].
LIU, Y ;
INGLE, JD .
ANALYTICAL CHEMISTRY, 1989, 61 (06) :520-524