EUROPEAN MULTICENTER COMPARISON OF TL-201 AND TC-99M METHOXYISOBUTYLISONITRILE IN ISCHEMIC-HEART-DISEASE

被引:21
作者
MAISEY, MN
LOWRY, A
BISCHOFDELALOYE, A
FRIDRICH, R
INGLESE, E
KHALIL, MN
VANDERSCHOOT, JB
机构
[1] CHU VAUDOIS,CH-1011 LAUSANNE,SWITZERLAND
[2] OSPED NIGUARDA CA GRANDA,MILAN,ITALY
[3] UNIV HOSP BASEL,CH-4031 BASEL,SWITZERLAND
[4] UNIV AMSTERDAM,AMSTERDAM,NETHERLANDS
[5] GROBY RD HOSP,LEICESTER LE3 9QE,ENGLAND
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1990年 / 16卷 / 12期
关键词
Coronary heart disease; Multi-centre comparison; Myocardial imaging; Technetium 99m methoxyisobutylisonitrile; Thallium; 201;
D O I
10.1007/BF01280254
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fifty-six patients in Europe were entered into a multi-centre study to compare the accuracy of technetium 99m methoxyisobutylisonitrile (99mTc-MIBI) for the detection of coronary artery disease (CAD) with thallium 201 (201T1) chloride perfusion scanning. The results showed a high degree of concordance between the two radiopharmaceuticals. Some 81% (678/840) of myocardial segments showed the same result (normal, infarct or ischaemia), and 80% (45/56) of patients had the same diagnosis. Overall detection of CAD in patients was 98% for201T1 and 96% for99mTc-MIBI. Detection of CAD in total arteries was 68% for both agents. In this study99mTc-MIBI was as accurate as201T1 for the detection of coronary artery stenoses. © 1990 Springer-Verlag.
引用
收藏
页码:869 / 872
页数:4
相关论文
共 11 条
[1]   METHOXYISOBUTYLISONITRILE (MIBI) TC-99M SPECT TO ESTABLISH A CORRELATE TO CORONARY FLOW RESERVE, THE PERFUSION RESERVE, FROM GLOBAL AND REGIONAL MYOCARDIAL UPTAKE AFTER EXERCISE AND REST [J].
BUELL, U ;
KAISER, HJ ;
DUPONT, F ;
UEBIS, R ;
KLEINHANS, E ;
HANRATH, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (01) :3-9
[2]  
CLAUSEN M, 1989, EUR J NUCL MED, V15, P661
[3]   QUANTITATIVE ROTATIONAL TOMOGRAPHY WITH TL-201 AND TC-99M 2-METHOXY-ISOBUTYL-ISONITRILE - A DIRECT COMPARISON IN NORMAL INDIVIDUALS AND PATIENTS WITH CORONARY-ARTERY DISEASE [J].
KAHN, JK ;
MCGHIE, I ;
AKERS, MS ;
SILLS, MN ;
FABER, TL ;
KULKARNI, PV ;
WILLERSON, JT ;
CORBETT, JR .
CIRCULATION, 1989, 79 (06) :1282-1293
[4]   COMPARISON OF TECHNETIUM-99M METHOXY ISOBUTYL ISONITRILE AND TL-201 FOR EVALUATION OF CORONARY-ARTERY DISEASE BY PLANAR AND TOMOGRAPHIC METHODS [J].
KIAT, H ;
MADDAHI, J ;
ROY, LT ;
VANTRAIN, K ;
FRIEDMAN, J ;
RESSER, K ;
BERMAN, DS .
AMERICAN HEART JOURNAL, 1989, 117 (01) :1-11
[5]  
MAJEED Q, 1989, NUCL MED COMMUN, V10, P210
[6]   THE EVALUATION OF VENTRICULAR-FUNCTION USING GATED MYOCARDIAL IMAGING WITH TC-99M MIBI [J].
NAJM, YC ;
TIMMIS, AD ;
MAISEY, MN ;
ELLAM, SV ;
MISTRY, R ;
CURRY, PVL ;
SOWTON, E .
EUROPEAN HEART JOURNAL, 1989, 10 (02) :142-148
[7]  
SINUSAS AJ, 1989, J NUCL MED, V30, P1456
[8]  
TAILLEFER R, 1989, EUR J NUCL MED, V15, P113
[9]   CLINICAL COMPARISON BETWEEN TL-201 AND TC-99M METHOXY ISOBUTYL ISONITRILE (HEXAMIBI) MYOCARDIAL PERFUSION IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE [J].
TAILLEFER, R ;
LAMBERT, R ;
DUPRAS, G ;
GREGOIRE, J ;
LEVEILLE, J ;
ESSIAMBRE, R ;
PHANEUF, DC .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (06) :280-286
[10]  
WACKERS FJT, 1989, J NUCL MED, V30, P301