A VIDEOFLUOROSCOPY METHOD FOR OPTICAL DISTORTION CORRECTION AND MEASUREMENT OF KNEE-JOINT KINEMATICS

被引:103
作者
BALTZOPOULOS, V
机构
[1] Department of Movement Science, University of Liverpool, Liverpool
关键词
FLUOROSCOPY; VIDEO; JOINT KINEMATICS; KNEE;
D O I
10.1016/0268-0033(95)92044-M
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Image distortion in video and image intensifier X-ray systems requires appropriate distortion correction meth ods to obtain accurate biomechanical quantitative measurements for joint kinematics applications. This paper presents an algorithm for coordinate reconstruction and distortion correction using a modified polynomial method. This algorithm was used for the measurement of patellar tendon moment arm, tibial plateau-tibial axis angle and patellar tendon-tibial axis angle during knee extension using videofluoroscopy in vivo. These parameters allow the determination of a two-dimensional biomechanical model of the knee for the measurement of muscle and joint forces during dynamic activities. Five males without knee joint injury history participated in the study. The mean measurement error obtained using an image intensifier-video system was 0.246 +/- 0.111 mm over a 180-mm x 180-mm field of view. The mean maximum patellar tendon moment arm was 39.87 mm at 44.9 degrees of knee flexion, The patellar tendon-tibial plateau angle was 112.9 degrees at full extension and decreased linearly to 87.6 degrees at 90 degrees of knee flexion. The mean angle between the tibial plateau and the tibial long axis was 84.8 degrees. Applications of the method include motion analysis using video and X-ray fluoroscopy systems with non-linear distortion problems. Relevance Accurate measurement of anatomical parameters from videofluoroscopy systems is important for the determination of joint biomechanical models and measurement of muscular and joint forces.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 34 条
[1]
Moeinzadeh, Engin, Akkas, Two-dimensional dynamic modelling of human knee joint, J Biomech, 16, pp. 253-264, (1983)
[2]
Yamaguchi, Zazac, A planar model of the knee joint to characterize the knee extensor mechanism, J Biomech, 22, pp. 1-10, (1989)
[3]
Nisell, Ericson, Nemeth, Ekholm, Tibiofemoral joint forces during isokinetic knee extension, Am J Sports Med, 17, pp. 49-54, (1989)
[4]
Eijden, Boer, Weijs, The orientation of the distal part of the quadriceps femoris muscle as a function of the knee flexion-extension angle, Journal of Biomechanics, 18, pp. 803-809, (1985)
[5]
Smidt, Biomechanical analysis of knee flexion and extension, J Biomech, 6, pp. 79-92, (1973)
[6]
Soudry, Lanir, Angel, Et al., Anatomy of the knee as seen by magnetic resonance imaging, J Bone Joint Surg, 68 B, pp. 117-120, (1986)
[7]
Selvik, Roentgen stereophotogrammetry A method for the study of the kinematics of the skeletal system, Acta Orthopaedica, 60, (1989)
[8]
DeLange, Huiskes, Kauer, Measurement errors in Roentgen-stereophotogrammetric jointmotion analysis, Journal of Biomechanics, 23, pp. 259-269, (1990)
[9]
Karrholm, Roentgen stereophotogrammetry review of orthopaedic applications, Acta Orthopaedica, 60, pp. 491-503, (1989)
[10]
Huiskes, Kremers, DeLange, Et al., Analytical stereophotogrammetric determination of three-dimensional knee-joint geometry, J Biomech, 18, pp. 559-570, (1985)