QUARTZ-CRYSTAL MICROBALANCE FOR IMMUNOSENSING

被引:27
作者
KOSSLINGER, C
DROST, S
ABERL, F
WOLF, H
机构
[1] UNIV REGENSBURG,INST MED MIKROBIOL & HYG,D-93042 REGENSBURG,GERMANY
[2] FRAUNHOFER INST FESTKORPERTECHNOL,D-80686 MUNICH,GERMANY
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1994年 / 349卷 / 05期
关键词
D O I
10.1007/BF00326598
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunosensing system is described for the detection of specific antibodies in human sera using a piezoelectric immunosensor and a flow through system. A quartz crystal microbalance theory, regarding mass and viscoelastic effects in multilayer systems, which is derived from the Mason circuit, gives the theoretical background for the interpretation of measurement data obtained from an oscillator circuit. An acoustic model for the antigen/antibody reaction is described (Part I). An immunospecific detector was developed by immobilizing synthetic peptides or recombinant proteins, comprising major diagnostic epitops of HIV, on the surface of the transducer. Attempts have been made to use the sensor for the initial screening for antibodies, specific against the Human Immunodeficiency Virus (HIV), in human serum samples. Results are obtained within a few minutes and with a selectivity comparable to a licensed HIV ELISA (Part II).
引用
收藏
页码:349 / 354
页数:6
相关论文
共 27 条
[1]  
ABERL F, 1992, GBF MONOG SERIES, V17, P123
[2]   CONTINUOUS LIQUID-PHASE PIEZOELECTRIC BIOSENSOR FOR KINETIC IMMUNOASSAYS [J].
DAVIS, KA ;
LEARY, TR .
ANALYTICAL CHEMISTRY, 1989, 61 (11) :1227-1230
[3]  
DIEULESAINT E, 1980, ELASTIC WAVES SOLIDS, P320
[4]   4-LAYER THEORY FOR THE ACOUSTIC SHEAR-WAVE SENSOR IN LIQUIDS INCORPORATING INTERFACIAL SLIP AND LIQUID STRUCTURE [J].
DUNCANHEWITT, WC ;
THOMPSON, M .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :94-105
[5]  
IKEDA T, 1990, FUNDAMENTALS PIEZOEL, P95
[6]  
KANAZAWA KK, 1985, ANAL CHIM ACTA, V175, P99
[7]   A QUARTZ CRYSTAL BIOSENSOR FOR MEASUREMENT IN LIQUIDS [J].
KOSSLINGER, C ;
DROST, S ;
ABERL, F ;
WOLF, H ;
KOCH, S ;
WOIAS, P .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (06) :397-404
[8]  
KOSSLINGER C, 1991, 6TH P INT C SOL STAT, P693
[9]   NANOTRIBOLOGY OF A KR MONOLAYER - A QUARTZ-CRYSTAL MICROBALANCE STUDY OF ATOMIC-SCALE FRICTION [J].
KRIM, J ;
SOLINA, DH ;
CHIARELLO, R .
PHYSICAL REVIEW LETTERS, 1991, 66 (02) :181-184
[10]   INVESTIGATION OF FILM-THICKNESS DETERMINATION BY OSCILLATING QUARTZ RESONATORS WITH LARGE MASS LOAD [J].
LU, CS ;
LEWIS, O .
JOURNAL OF APPLIED PHYSICS, 1972, 43 (11) :4385-&