Restriction of both oxygen influx to the cornea and carbon dioxide efflux from the cornea by contact lenses results in adverse tissue changes. We measured the extent of hypoxia and hypercapnia at the corneal surface of 10 human volunteers during static, dynamic (blinking), and closed-eye wear of hydrogel and nonhydrogel contact lenses of different gas transmissibilities. During open-eye wear, hypoxia and hypercapnia are lower beneath lenses of higher oxygen and carbon dioxide transmissibilities, respectively (p<0.001). Blinking plays a significant role in alleviating corneal hypoxia (p<0.05), but not hypercapnia, during lens wear. In the absence of lenses, the gaseous tensions at the anterior corneal surface during eye closure were: pO2=37.4 ± 20.9 mm Hg and pCO2=39.3 ±3.1 mm Hg. Closed-eye lens wear resulted in greater levels of hypoxia and hypercapnia that were directly correlated with lens transmissibility (p<0.001). These data form the basis of models for predicting adverse tissue changes during contact lens wear and suggest prophylactic and therapeutic clinical strategies for alleviating lens-induced hypoxia and hypercapnia. © 1990 American Academy of Optometry.
引用
收藏
页码:512 / 521
页数:10
相关论文
共 55 条
[1]  
Smelser G.K., Ozanics V., Importance of atmospheric oxygen for maintenance of the optical properties of the human cornea, Science, 115, (1952)
[2]  
Masters B.R., Falk S., Chance B., In vivo flavoprotein redox measurements of rabbit corneal normoxic-anoxic transitions, Curr Eye Res, 1, pp. 623-627, (1982)
[3]  
Hamano H., Hori M. Effect of contact lens wear on the mitoses of corneal epithelial cells. Preliminary report, Contact Lens Assoc Ophthalmol J, 9, pp. 133-136, (1983)
[4]  
Efron N., Carney L.G., Recovery of the human cornea from anoxic stress, Int Contact Lens Clin, 9, pp. 244-246, (1982)
[5]  
Holden B.A., Sweeny D.F., Vannas A., Nilsson K.T., Efron N., Effects of long-term extended contact lens wear on the human cornea, Invest Ophthalmol Vis Sci, 26, pp. 1489-1501, (1985)
[6]  
Lowther G.E., Hill R.M., Recovery of the corneal epithelium after a period of anoxia, Am J Optom Arch am Acad Optom, 50, pp. 234-241, (1973)
[7]  
Kenyon E., Poise K.A., Seger R.G., Influence of wearing schedule on extended wear complications, Ophthalmology (Rochester), 93, pp. 231-236, (1986)
[8]  
Bergmanson J., Histopathological analysis of the corneal epithelium after contact lens wear, J am Optom Assoc, 58, pp. 812-818, (1987)
[9]  
Lebow K.A., Plishka K., Ocular changes associated with extended wear contact lenses, Int Contact Lens Clin, 7, pp. 49-55, (1980)
[10]  
Poise K.A., Mandell R.B., Critical oxygen tension at the corneal surface, Arch Ophthalmol, 84, pp. 505-508, (1970)