DEBLURRING FOR NON-2D FOURIER-TRANSFORM MAGNETIC-RESONANCE-IMAGING

被引:169
作者
NOLL, DC [1 ]
PAULY, JM [1 ]
MEYER, CH [1 ]
NISHIMURA, DG [1 ]
MACOVSKI, A [1 ]
机构
[1] DEPT ELECT ENGN,MAGNET RESONANCE SYST RES LAB,STANFORD,CA 94305
关键词
D O I
10.1002/mrm.1910250210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For several non‐2D Fourier transform imaging methods, off‐resonant reconstruction does not just cause geometric distortion, but changes the shape of the point spread function and causes blurring. This effect is well known for projection reconstruction and spiral k‐space scanning sequences. We introduce here a method that automatically removes blur introduced by magnetic field inhomogeneity and susceptibility without using a resonant frequency map, making these imaging methods more useful. In this method, the raw data are modulated to several different frequencies and reconstructed to create a series of base images. Determination of degree of blur is done by calculating a focusing measure for each point in each base image and a composite image is then constructed using only the unblurred regions from each base image. This method has been successfully applied to phantom and in vivo images using projection‐reconstruction and spiral‐scan sequences. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:319 / 333
页数:15
相关论文
共 31 条
  • [1] HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1.
    AHN, CB
    KIM, JH
    CHO, ZH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) : 2 - 7
  • [2] LUNG PARENCHYMA - MAGNETIC-SUSCEPTIBILITY IN MR IMAGING
    BERGIN, CJ
    GLOVER, GH
    PAULY, JM
    [J]. RADIOLOGY, 1991, 180 (03) : 845 - 848
  • [3] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [4] IMPROVED DETECTABILITY IN LOW SIGNAL-TO-NOISE RATIO MAGNETIC-RESONANCE IMAGES BY MEANS OF A PHASE-CORRECTED REAL RECONSTRUCTION
    BERNSTEIN, MA
    THOMASSON, DM
    PERMAN, WH
    [J]. MEDICAL PHYSICS, 1989, 16 (05) : 813 - 817
  • [5] BRACEWELL R, 1978, FOURIER TRANSFORM IT
  • [6] SHARPENING STELLAR IMAGES
    BUFFINGTON, A
    CRAWFORD, FS
    POLLAINE, SM
    ORTH, CD
    MULLER, RA
    [J]. SCIENCE, 1978, 200 (4341) : 489 - 494
  • [7] SPIN WARP NMR IMAGING AND APPLICATIONS TO HUMAN WHOLE-BODY IMAGING
    EDELSTEIN, WA
    HUTCHISON, JMS
    JOHNSON, G
    REDPATH, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04) : 751 - 756
  • [8] NOVEL TECHNOLOGIES FOR AUTOMATIC FOCUSING AND WHITE BALANCING OF SOLID-STATE COLOR VIDEO CAMERA
    HANMA, K
    MASUDA, M
    NABEYAMA, H
    SAITO, Y
    [J]. IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1983, 29 (03) : 376 - 382
  • [9] JACKSON JI, 1990, 9TH P ANN M SOC MAGN, P428
  • [10] NMR FOURIER ZEUGMATOGRAPHY
    KUMAR, A
    WELTI, D
    ERNST, RR
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1975, 18 (01) : 69 - 83