COMPARISON OF 6 COMMERCIAL TECHNIQUES IN THE MEASUREMENT OF MICROALBUMINURIA IN DIABETIC-PATIENTS

被引:41
作者
TIU, SC
LEE, SS
CHENG, MW
机构
[1] Medical Unit 'A', Queen Elizabeth Hospital, Kowloon, Wylie Road
关键词
D O I
10.2337/diacare.16.4.616
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE- To evaluate the advantages and drawbacks of six commercially available techniques in the measurement of microalbuminuria in diabetic patients. RESEARCH DESIGN AND METHODS - Timed overnight urine samples from 75 patients in our diabetic clinic were tested with 2 qualitative tests (Micral-Test and Microbumintest) and assayed with 4 quantitative tests, which used different methodologies: double-antibody RIA, RID, IT, and NEPH. All tests were commercially available. The double-antibody RIA was taken as the golden standard. All urine samples were either negative or trace by Albustix (Ames, Elkhart, IN). Interobserver variation for the 2 qualitative tests was assessed by asking 12 experienced nurses to read the color changes on the dipsticks and the tablets simultaneously, using test solutions with albumin concentrations of 16, 32, and 64 mg/L. RESULTS- The 75 urine samples contained 0-154.2 mg/L of albumin. Correlation coefficients of RID, NEPH, and IT with RIA were 0.970, 0.975, and 0.974, respectively. intra-assay and interassay CVs ranged from 1.36-11.5%. Microbumintest had a higher sensitivity (100 vs. 75%), but lower specificity (82.5 vs. 87.3%) than Micral-Test. Considerable interobserver variation existed in the matching of colors for both tests. Discrepancies were especially significant with Microbumintest, with 8 of 12 nurses misreading the 32 mg/L level. CONCLUSIONS - Correlations of the 3 quantitative methods with RIA were all >0.970. Choice of test may depend more on considerations such as time, space, number of specimens to be handled, and availability of instruments. Both qualitative tests showed a relatively low specificity. Positive tests must be confirmed with quantitative assays before microalbuminuria is diagnosed. Microbumintest had a higher sensitivity, but its unacceptably high interobserver variation and lower specificity were serious drawbacks.
引用
收藏
页码:616 / 620
页数:5
相关论文
共 16 条
[1]   EFFECT OF PROTEIN RESTRICTION IN INSULIN-DEPENDENT DIABETICS AT RISK OF NEPHROPATHY [J].
COHEN, D ;
DODDS, R ;
VIBERTI, G .
BRITISH MEDICAL JOURNAL, 1987, 294 (6575) :795-798
[2]   THE VARIABILITY OF OVERNIGHT URINARY ALBUMIN EXCRETION IN INSULIN-DEPENDENT DIABETIC AND NORMAL SUBJECTS [J].
COHEN, DL ;
CLOSE, CF ;
VIBERTI, GC .
DIABETIC MEDICINE, 1987, 4 (05) :437-440
[3]   REDUCTION OF URINARY ALBUMIN EXCRETION AFTER 4 YEARS OF CONTINUOUS SUBCUTANEOUS INSULIN INFUSION IN INSULIN-DEPENDENT DIABETES-MELLITUS - THE OSLO STUDY [J].
DAHLJORGENSEN, K ;
HANSSEN, KF ;
KIERULF, P ;
BJORO, T ;
SANDVIK, L ;
AAGENAES, O .
ACTA ENDOCRINOLOGICA, 1988, 117 (01) :19-25
[4]   COMPARISON OF OVERNIGHT, MORNING AND 24-HOUR URINE COLLECTIONS IN THE ASSESSMENT OF DIABETIC MICROALBUMINURIA [J].
ESHOJ, O ;
FELDTRASMUSSEN, B ;
LARSEN, ML ;
MOGENSEN, EF .
DIABETIC MEDICINE, 1987, 4 (06) :531-533
[5]  
Feldt-Rasmussen B, 1984, DIABETIC NEPHROPATHY, V3, P101
[6]   DESIRABLE PERFORMANCE STANDARDS FOR CLINICAL-CHEMISTRY TESTS [J].
FRASER, CG .
ADVANCES IN CLINICAL CHEMISTRY, 1983, 23 :299-339
[7]   TURBIDIMETRIC MEASUREMENT OF MICROALBUMINURIA [J].
HARMOINEN, A ;
VUORINEN, P ;
JOKELA, H .
CLINICA CHIMICA ACTA, 1987, 166 (01) :85-89
[8]   URINARY ALBUMIN MEASUREMENT BY IMMUNOTURBIDIMETRY [J].
LLOYD, DR ;
HINDLE, EJ ;
MARPLES, J ;
GATT, JA .
ANNALS OF CLINICAL BIOCHEMISTRY, 1987, 24 :209-210
[9]   PREVENTION OF DIABETIC NEPHROPATHY WITH ENALAPRIL IN NORMOTENSIVE DIABETICS WITH MICROALBUMINURIA [J].
MARRE, M ;
CHATELLIER, G ;
LEBLANC, H ;
GUYENE, TT ;
MENARD, J ;
PASSA, P .
BMJ-BRITISH MEDICAL JOURNAL, 1988, 297 (6656) :1092-1095
[10]   PREDICTING DIABETIC NEPHROPATHY IN INSULIN-DEPENDENT PATIENTS [J].
MOGENSEN, CE ;
CHRISTENSEN, CK .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (02) :89-93