EXTERNALLY ACTIVATED ANTITACHYCARDIA PACEMAKER WITH NONINVASIVE ELECTROPHYSIOLOGIC RE-TESTING CAPABILITY

被引:8
作者
AONUMA, K
ROZANSKI, JJ
BAROLD, SS
DEWITT, PL
GOSSELIN, AJ
LISTER, JW
机构
[1] GENESEE HOSP,ROCHESTER,NY 14607
[2] MIAMI HEART INST,4701 N MERIDAN AVE,MIAMI BEACH,FL 33140
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1985年 / 8卷 / 02期
关键词
D O I
10.1111/j.1540-8159.1985.tb05752.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:215 / 224
页数:10
相关论文
共 13 条
[1]  
BAROLD SS, 1982, CARDIAC IMPULSE, V3
[2]   A VERSATILE PACEMAKER SYSTEM FOR TERMINATION OF TACHYCARDIAS [J].
DENDULK, K ;
BERTHOLET, M ;
BRUGADA, P ;
BAR, FW ;
RICHARDS, D ;
DEMOULIN, JC ;
WALEFFE, A ;
BAKELS, N ;
LINDEMANS, FW ;
BOURGEOIS, I ;
KULBERTUS, HE ;
WELLENS, HJJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (07) :731-738
[3]   DDD DDT PACEMAKERS IN THE TREATMENT OF VENTRICULAR-TACHYCARDIA [J].
FISHER, JD ;
FURMAN, S ;
KIM, SG ;
MATOS, JA ;
WASPE, LE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (02) :173-178
[4]   PATIENT-ACTIVATED TRANSVENOUS CARDIAC STIMULATION FOR THE TREATMENT OF SUPRAVENTRICULAR AND VENTRICULAR-TACHYCARDIA [J].
HARTZLER, GO ;
HOLMES, DR ;
OSBORN, MJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (04) :903-909
[5]  
HERRE JM, 1983, J AM COLL CARDIOL, V1, P719
[6]   PRESENT STATE OF INDUSTRIAL-DEVELOPMENT OF DEVICES [J].
JENKINS, J ;
ARZBAECHER, R ;
MARTIN, R ;
DUFFIN, E ;
TARJAN, P ;
GILLI, N ;
GILLETTE, P ;
FURMAN, S ;
GRIFFIN, J ;
CAMM, J ;
BILITCH, M ;
WENGER, N ;
BRILLER, S ;
HAUSER, R ;
NAPPHOLZ, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03) :557-568
[7]   THERAPEUTIC PACING IN TACHYARRHYTHMIAS BY IMPLANTED PACEMAKERS [J].
LUDERITZ, B ;
DALNONCOURT, CN ;
STEINBECK, G ;
BEYER, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1982, 5 (03) :366-371
[8]   CLINICAL-EVALUATION OF AN ADAPTIVE TACHYCARDIA INTERVENTION PACEMAKER WITH AUTOMATIC CYCLE LENGTH ADJUSTMENT [J].
NATHAN, A ;
HELLESTRAND, K ;
BEXTON, R ;
NAPPHOLZ, T ;
SPURRELL, R ;
CAMM, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1982, 5 (02) :201-207
[9]   INITIAL EXPERIENCE WITH A FULLY IMPLANTABLE, PROGRAMMABLE, SCANNING, EXTRASTIMULUS PACEMAKER FOR TACHYCARDIA TERMINATION [J].
NATHAN, AW ;
CAMM, AJ ;
BEXTON, RS ;
HELLESTRAND, KJ ;
SPURRELL, RAJ .
CLINICAL CARDIOLOGY, 1982, 5 (01) :22-26
[10]   RADIOFREQUENCY-TRIGGERED PACEMAKERS - USES AND LIMITATIONS - LONG-TERM STUDY [J].
PETERS, RW ;
SHAFTON, E ;
FRANK, S ;
THOMAS, AN ;
SCHEINMAN, MM .
ANNALS OF INTERNAL MEDICINE, 1978, 88 (01) :17-22