ASSESSMENT OF SEVERITY OF MITRAL REGURGITATION BY MEASURING REGURGITANT JET WIDTH AT ITS ORIGIN WITH TRANSESOPHAGEAL DOPPLER COLOR FLOW IMAGING

被引:130
作者
TRIBOUILLOY, C [1 ]
SHEN, WF [1 ]
QUERE, JP [1 ]
REY, JL [1 ]
CHOQUET, D [1 ]
DUFOSSE, H [1 ]
LESBRE, JP [1 ]
机构
[1] UNIV PICARDIE,HOP SUD,DEPT CARDIOL,SERV CARDIOL B,F-80054 AMIENS,FRANCE
关键词
MITRAL REGURGITATION; ECHOCARDIOGRAPHY; TRANSESOPHAGEAL; DOPPLER; ANGIOGRAPHY;
D O I
10.1161/01.CIR.85.4.1248
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The ability of transesophageal color Doppler echocardiography to provide high-resolution images of both cardiac structure and blood flow in real time is advantageous for many clinical purposes. This study was performed to determine the utility of the regurgitant jet width at its origin measured by transesophageal Doppler color flow imaging in the assessment of severity of mitral regurgitation. Methods and Results. Sixty-three consecutive patients with mitral regurgitation underwent transesophageal color Doppler examination, and the diameter of regurgitant jet at its origin was measured. Both right and left cardiac catheterizations were performed within 24 hours of Doppler studies, and angiographic grading of mitral regurgitation and regurgitant stroke volume were evaluated. There was a close relation between the jet diameter at its origin measured by transesophageal Doppler color flow imaging and the angiographic grade of mitral regurgitation (r = 0.86, p < 0.001). A jet diameter of 5.5 mm or more identified severe mitral regurgitation (grade III or IV) with a sensitivity of 92%, specificity of 92%, and positive and negative predictive values of 88% and 95%, respectively. In 31 patients with isolated mitral regurgitation, the jet diameter correlated well with the regurgitant stroke volume determined by a combined hemodynamic-angiographic method (r = 0.85, p < 0.001). A jet diameter of 5.5 mm or more identified a regurgitant stroke volume of 60 ml or more with a sensitivity of 88%, specificity of 93%, and positive and negative predictive values of 94% and 87%, respectively. Conclusions. The regurgitant jet width at its origin measured by transesophageal Doppler color flow imaging provides a simple and useful method of measuring the severity of mitral regurgitation, and it may allow differentiation between mild and severe mitral regurgitation.
引用
收藏
页码:1248 / 1253
页数:6
相关论文
共 26 条
[1]   QUANTITATION OF AORTIC REGURGITATION BY COLOR CODED CROSS-SECTIONAL DOPPLER ECHOCARDIOGRAPHY [J].
BAUMGARTNER, H ;
KRATZER, H ;
HELMREICH, G ;
KUHN, P .
EUROPEAN HEART JOURNAL, 1988, 9 (04) :380-387
[2]  
Baumgartner H, 1991, J Am Soc Echocardiogr, V4, P57
[3]   COMPUTER-ANALYSIS OF DOPPLER COLOR FLOW MAPPING IMAGES FOR QUANTITATIVE ASSESSMENT OF INVITRO FLUID JETS [J].
BOLGER, AF ;
EIGLER, NL ;
PFAFF, JM ;
RESSER, KJ ;
MAURER, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :450-457
[4]  
Cooper J W, 1989, J Am Soc Echocardiogr, V2, P56
[5]  
HEIMELMAN RB, 1991, J AM COLL CARDIOL, V17, P272
[6]  
HOLEN J, 1990, ULTRASOUND MED BIOL, V16, P6543
[7]   INTRAOPERATIVE COLOR DOPPLER ASSESSMENT IN VALVE REPAIR SURGERY [J].
MAURER, G ;
CZER, LSC .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1991, 8 (02) :263-271
[8]  
Nicolosi G L, 1990, J Am Soc Echocardiogr, V3, P435
[9]  
OSLEN LJ, 1987, MAYO CLIN P, V62, P22
[10]   A NEW METHOD FOR QUANTIFICATION OF REGURGITANT FLOW-RATE USING COLOR DOPPLER FLOW IMAGING OF THE FLOW CONVERGENCE REGION PROXIMAL TO A DISCRETE ORIFICE - AN INVITRO STUDY [J].
RECUSANI, F ;
BARGIGGIA, GS ;
YOGANATHAN, AP ;
RAISARO, A ;
VALDESCRUZ, LM ;
SUNG, HW ;
BERTUCCI, C ;
GALLATI, M ;
MOISES, VA ;
SIMPSON, IA ;
TRONCONI, L ;
SAHN, DJ .
CIRCULATION, 1991, 83 (02) :594-604