CAN MEASUREMENTS OF POTENTIAL DOUBLING TIME (T-POT) BE COMPARED BETWEEN LABORATORIES - A QUALITY-CONTROL STUDY

被引:30
作者
HAUSTERMANS, K [1 ]
HOFLAND, I [1 ]
POTTIE, G [1 ]
RAMAEKERS, M [1 ]
BEGG, AC [1 ]
机构
[1] NETHERLANDS CANC INST,DEPT EXPTL THERAPY,1066 CX AMSTERDAM,NETHERLANDS
来源
CYTOMETRY | 1995年 / 19卷 / 02期
关键词
PREDICTIVE ASSAYS; BROMODEOXYURIDINE; IODODEOXYURIDINE; FLOW CYTOMETRY; QUALITY CONTROL;
D O I
10.1002/cyto.990190210
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The purpose of this study was to investigate the reproducibility of potential doubling time measurements of human tumors in different laboratories and to distinguish which steps in the measurement procedure were subject to the greatest variation, This was achieved by comparing measurements on the same source material in two different laboratories in which three aspects of the technique were separately studied, namely, preparation and staining of the nuclear suspensions, running the samples on the now cytometer (FCM), and analyzing the two-parameter FCM data. This involved exchange between the two centers of fixed tumor material, stained nuclear suspensions, and FCM data on floppy disks. The analysis step was found to be the least variable step. For DNA synthesis time, T-S, and the labeling index, LI, the coefficients of determination (R(2)) ranged from 92% to 95.4%. A small systematic bias was observed, with one center measuring approximately 15% higher values for both LI and T-S. Different criteria for window placements were found to be a contributing factor. Variations in the FCM step were approximately equal to those for analysis, with no systematic deviations. Variations for the preparation and staining step were the largest (R(2) = 60.5% and 38.1% for LI and T-S, respectively). However, this step was the only one subject to intratumoral variability, which was the largest contributing factor to the variations observed. In addition, however, LI was on average 41% higher in one center compared to the other, resulting in a systematic bias. Differences in the level of green fluorescence of the labeled cells implicated antibody differences as a possible cause. The variations found here for the three procedural aspects were significantly smaller than variations observed between tumors, a requirement for a predictive assay. Suggestions for implementation of quality control procedures include objective (computer-assisted) data analysis on two-parameter histograms and optimization of antibody combinations. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:154 / 163
页数:10
相关论文
共 14 条
[1]   ACCELERATED VERSUS CONVENTIONAL FRACTIONATION IN THE POSTOPERATIVE IRRADIATION OF LOCALLY ADVANCED HEAD AND NECK-CANCER - INFLUENCE OF TUMOR PROLIFERATION [J].
AWWAD, HK ;
KHAFAGY, Y ;
BARSOUM, M ;
EZZAT, S ;
ELATTAR, I ;
FARAG, H ;
AKOUSH, H ;
MEABID, H ;
ZAGHLOUL, MS .
RADIOTHERAPY AND ONCOLOGY, 1992, 25 (04) :261-266
[2]   HUMAN-TUMOR CELL-KINETICS USING A MONOCLONAL-ANTIBODY AGAINST IODODEOXYURIDINE - INTRATUMOR SAMPLING VARIATIONS [J].
BEGG, AC ;
MOONEN, L ;
HOFLAND, I ;
DESSING, M ;
BARTELINK, H .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) :337-347
[3]  
BEGG AC, 1992, SEMIN RADIAT ONCOL, V1, P22
[4]   TUMOR PROLIFERATION ASSESSED BY COMBINED HISTOLOGICAL AND FLOW CYTOMETRIC ANALYSIS - IMPLICATIONS FOR THERAPY IN SQUAMOUS-CELL CARCINOMA IN THE HEAD AND NECK [J].
BENNETT, MH ;
WILSON, GD ;
DISCHE, S ;
SAUNDERS, MI ;
MARTINDALE, CA ;
ROBINSON, BM ;
OHALLORAN, AE ;
LESLIE, MD ;
LAING, JHE .
BRITISH JOURNAL OF CANCER, 1992, 65 (06) :870-878
[5]   IN-VIVO MEASUREMENT OF THE POTENTIAL DOUBLING TIME BY FLOW-CYTOMETRIC IN OROPHARYNGEAL CANCER TREATED BY CONVENTIONAL RADIOTHERAPY [J].
BOURHIS, J ;
WILSON, G ;
WIBAULT, P ;
BOSQ, J ;
CHAVAUDRA, N ;
JANOT, F ;
LUBOINSKI, B ;
ESCHWEGE, F ;
MALAISE, EP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (05) :793-799
[6]   POTENTIAL DOUBLING TIME IN HEAD AND NECK TUMORS TREATED BY PRIMARY RADIOTHERAPY - PRELIMINARY EVIDENCE FOR A PROGNOSTIC-SIGNIFICANCE IN LOCAL-CONTROL [J].
CORVO, R ;
GIARETTI, W ;
SANGUINETI, G ;
GEIDO, E ;
ORECCHIA, R ;
BARRA, S ;
MARGARINO, G ;
BACIGALUPO, A ;
VITALE, V .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05) :1165-1172
[7]  
HAUSTERMANS K, IN PRESS EUR J CANCE
[8]   TUMOR-CELL KINETICS, LOCAL TUMOR-CONTROL, AND ACCELERATED RADIOTHERAPY - A PRELIMINARY-REPORT [J].
LOCHRIN, CA ;
WILSON, GD ;
MCNALLY, NJ ;
DISCHE, S ;
SAUNDERS, MI .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (01) :87-91
[9]   PROLIFERATION INDEXES OF INVASIVE BREAST CARCINOMAS AFTER INVIVO 5-BROMO-2'-DEOXYURIDINE LABELING - A FLOW CYTOMETRIC STUDY OF 75 TUMORS [J].
REW, DA ;
CAMPBELL, ID ;
TAYLOR, I ;
WILSON, GD .
BRITISH JOURNAL OF SURGERY, 1992, 79 (04) :335-339
[10]  
Steel G.G., 1977, GROWTH KINETICS TUMO