EVALUATION OF MITRAL-STENOSIS WITH VELOCITY-ENCODED CINE-MAGNETIC RESONANCE IMAGING

被引:32
作者
HEIDENREICH, PA
STEFFENS, J
FUJITA, N
OSULLIVAN, M
CAPUTO, GR
FOSTER, E
HIGGINS, CB
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,MRI SECT,SAN FRANCISCO,CA 94142
[2] UNIV CALIF SAN FRANCISCO,DIV CARDIOL,SAN FRANCISCO,CA 94142
关键词
D O I
10.1016/S0002-9149(99)80555-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Velocity-encoded cine-magnetic resonance imaging (VEC-MRI) is a new method for quantitation of blood flow with the potential to measure high-velocity jets across stenotic valves. The objective of this study was to evaluate the ability of VEC-MRI to measure transmitral velocity in patients with mitral stenosis. Sixteen patients with known mitral stenosis were studied. A 1.5 Tesla superconducting magnet was used to obtain velocity-encoded images in the left ventricular short-axis plane. Images were obtained throughout the cardiac cycle at 3 consecutive slices beginning proximal to the mitral coaptation point. To determine the optimal slice thickness for MRI imaging, both 10 mm and 5 mm thicknesses were used. Echocardiography including continuous-wave Doppler was performed on every patient within 2 hours of MRI imaging. Peak velocity was determined for both VEC-MRI and Doppler-echo images. Two observers independently measured the VEC-MRI mitral inflow velocities. Of the 16 patients, imaged data were incomplete in only 1 study, and all images were adequate for analysis. Strong correlations were found for measurements of mitral valve gradient for both 10 mm (peak r = 0.89, mean r = 0.84) and 5 mm (peak r = 0.82, mean r = 0.95) slice thicknesses. Measurements of peak velocity with VEC-MRI (10 mm) agreed well with Doppler: mean 1.46 m/s, mean of differences (Doppler MRI) 0.38 m/s, standard deviation of differences 0.2 m/s. These findings suggest that VEC-MRI can noninvasively determine the severity of mitral stenosis.
引用
收藏
页码:365 / 369
页数:5
相关论文
共 18 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] CRANNEY GB, 1991, CIRCULATION, P1216
  • [3] DIJK PV, 1984, J COMPUT ASSIST TOMO, V8, P429
  • [4] VELOCITY-ENCODED CINE MRI IN THE EVALUATION OF LEFT-VENTRICULAR DIASTOLIC FUNCTION - MEASUREMENT OF MITRAL-VALVE AND PULMONARY VEIN FLOW VELOCITIES AND FLOW VOLUME ACROSS THE MITRAL-VALVE
    HARTIALA, JJ
    MOSTBECK, GH
    FOSTER, E
    FUJITA, N
    DULCE, MC
    CHAZOUILLERES, AF
    HIGGINS, CB
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (04) : 1054 - 1066
  • [5] FUNCTIONAL-EVALUATION OF THE HEART WITH MAGNETIC-RESONANCE IMAGING
    HIGGINS, CB
    HOLT, W
    PFLUGFELDER, P
    SECHTEM, U
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (02) : 121 - 139
  • [6] HIGGINS CB, 1991, CIRCULATION, P1198
  • [7] MAGNETIC-RESONANCE JET VELOCITY MAPPING IN MITRAL AND AORTIC-VALVE STENOSIS
    KILNER, PJ
    MANZARA, CC
    MOHIADDIN, RH
    PENNELL, DJ
    SUTTON, MGS
    FIRMIN, DN
    UNDERWOOD, SR
    LONGMORE, DB
    [J]. CIRCULATION, 1993, 87 (04) : 1239 - 1248
  • [8] VALVE AND GREAT VESSEL STENOSIS - ASSESSMENT WITH MR JET VELOCITY MAPPING
    KILNER, PJ
    FIRMIN, DN
    REES, RSO
    MARTINEZ, J
    PENNELL, DJ
    MOHIADDIN, RH
    UNDERWOOD, SR
    LONGMORE, DB
    [J]. RADIOLOGY, 1991, 178 (01) : 229 - 235
  • [9] RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION
    KONDO, C
    CAPUTO, GR
    SEMELKA, R
    FOSTER, E
    SHIMAKAWA, A
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) : 9 - 16
  • [10] LOW-FIELD CINE MAGNETIC-RESONANCE IMAGING IN AORTIC-VALVE DISEASE
    METCALFE, MJ
    JONES, RA
    REDPATH, TW
    SMITH, FW
    JENNINGS, K
    WALTON, S
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (744) : 1063 - 1066