SEGMENTAL ANALYSIS OF SPECT TC-99M-METHOXY ISOBUTYL ISONITRILE AND TL-201 MYOCARDIAL IMAGING IN ISCHEMIC-HEART-DISEASE

被引:8
作者
HASSAN, IM
MOHAMMED, MMJ
CONSTANTINIDES, C
SADEK, S
NAIR, M
BELANI, N
YOUSEF, AM
ABDELDAYEM, HM
机构
[1] KUWAIT UNIV, DEPT NUCL MED, POB 24923, SAFAT 13110, KUWAIT
[2] MINIST PUBL HLTH KUWAIT, KUWAIT, KUWAIT
[3] KUWAIT UNIV, DEPT CARDIOL, SAFAT 13110, KUWAIT
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1990年 / 16卷 / 8-10期
关键词
!sup]99m[!/sup]Tc-MIBI; Ischaemic heart diseases; Myocardial imaging;
D O I
10.1007/BF00998173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To study the potential usefulness of99mTc-methoxy isobutyl isonitrile (99mTc-MIBI) as a substitute for201Tl in assessing patients with ischaemic heart disease, 24 patients underwent 1 day rest and exercise99mTc-MIBI single photon emission computerised topography (SPECT) 1 week after SPECT exercise201Tl. All patients were catheterized within 1 month after myocardial imaging. In 17 patients, resting first pass radionuclide angiography (FPRNA) was performed with99mTc-MIBI. The heart to lung ratio for99mTc-MIBI and201Tl was calculated both at rest and exercise. The segmental analysis for myocardial perfusion reveals that 87/96 segments (91 %) were correctly classified by SPECT201Tl and 84/96 segments (88%) were correctly classified by99mTc-MIBI. A significant correlation was present between LVEF measured by99mTc-MIBI FPRNA and contrast ventriculography (r = 0.85, P < 0.0001). The heart to lung ratio both at rest and exercise for99mTc-MIBI is significantly higher than201Tl (P < 0.01 and <0.001 respectively). We conclude that99mTc-MIBI is a promising agent for simultaneous evaluation of myocardial perfusion and cardiac function. © 1990 Springer-Verlag.
引用
收藏
页码:705 / 711
页数:7
相关论文
共 19 条
[1]  
ABDELDAYEM HM, 1988, EUR J NUCL MED, V14, P284
[2]  
BAILLET GY, 1989, J NUCL MED, V30, P38
[3]   QUANTITATIVE ROTATIONAL TL-201 TOMOGRAPHY FOR IDENTIFYING AND LOCALIZING CORONARY-ARTERY DISEASE [J].
DEPASQUALE, EE ;
NODY, AC ;
DEPUEY, EG ;
GARCIA, EV ;
PILCHER, G ;
BREDLAU, C ;
ROUBIN, G ;
GOBER, A ;
GRUENTZIG, A ;
DAMATO, P ;
BERGER, HJ .
CIRCULATION, 1988, 77 (02) :316-327
[4]  
DEPUEY EG, 1988, J NUCL MED, V29, P1479
[5]  
FABER T L, 1988, Journal of Nuclear Medicine, V29, P805
[6]   PROBLEMS OF DUODENOGASTRIC REFLUX IN TC-99M HEXA MIBI PLANAR, TOMOGRAPHIC AND BULLS EYE DISPLAY [J].
HASSAN, IM ;
MOHAMMAD, MMJ ;
CONSTANTINIDES, C ;
NAIR, M ;
BELANI, N ;
ABDELDAYEM, HM .
CLINICAL NUCLEAR MEDICINE, 1989, 14 (04) :286-289
[7]  
HASSAN IM, 1988, EUR J NUCL MED, V14, P250
[8]  
Herman G.T, 1979, IMAGE RECONSTRUCTION
[9]  
HOLMAN BL, 1987, J NUCL MED, V28, P13
[10]  
HOLMAN BL, 1984, HEART DISEASE TXB CA, P351