SINGLE VERSUS DOUBLE OCCLUSIVE DRESSING TECHNIQUE TO MINIMIZE INFUSION THROMBOPHLEBITIS - VIALON AND TEFLON CANNULAE REASSESSED

被引:3
作者
MYLES, PS
BUCKLAND, MR
BURNETT, WJ
机构
关键词
EQUIPMENT; INTRAVENOUS CATHETERS; PERIPHERAL; TEFLON; VIALON; OCCLUSIVE DRESSING; OPSITE; COMPLICATIONS; THROMBOSIS; VEINS; CANNULATION; THROMBOPHLEBITIS;
D O I
10.1177/0310057X9101900406
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Infusion thrombophlebitis is the commonest complications of intravenous cannulation. This study was undertaken to prospectively evaluate a double-occlusive dressing technique and a new cannula, bismuth oxide-Teflon(R) (Critikon Inc., Aust.), comparing it to Vialon(R) (Deseret Medical Inc., Utah, USA). The study group of two hundred patients had a 16 gauge intravenous cannula inserted in theatre using a standard technique. The incidence of thrombophlebitis was determined on a daily basis. Cannula tips were sent for culture on removal. Vialon(R) was found to be superior to Teflon(R) after day 1. Although a double-occlusive dressing technique increased the duration of cannulation (50.9 vs. 41.9 hours, P < 0.05), there was no difference in the incidence of thrombophlebitis. Neither cannula material nor dressing technique had an influence on the results of cannula tip culture (6% incidence). There was no evidence of bacteraemia in any case.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 17 条
[1]   POSTINFUSION THROMBOPHLEBITIS - EFFECT OF INTRAVENOUS DRUGS USED IN ANESTHESIA [J].
BOON, J ;
BEEMER, GH ;
BAINBRIDGE, DJM ;
CRANKSHAW, DP .
ANAESTHESIA AND INTENSIVE CARE, 1981, 9 (01) :23-27
[2]  
Dinley RJ, 1976, CURR MED RES OPIN, V3, P607
[3]   INTRAVASCULAR-DEVICE INFECTIONS [J].
ELLIOTT, TSJ .
JOURNAL OF MEDICAL MICROBIOLOGY, 1988, 27 (03) :161-167
[4]   RISK-FACTORS ASSOCIATED WITH INTRAVASCULAR CATHETER INFECTIONS IN BURNED PATIENTS - A PROSPECTIVE, RANDOMIZED STUDY [J].
FRANCESCHI, D ;
GERDING, RL ;
PHILLIPS, G ;
FRATIANNE, RB .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1989, 29 (06) :811-816
[5]   INFUSION THROMBOPHLEBITIS - A PROSPECTIVE COMPARISON OF 645 VIALON AND TEFLON CANNULAE IN ANESTHETIC AND POSTOPERATIVE USE [J].
GAUKROGER, PB ;
ROBERTS, JG ;
MANNERS, TA .
ANAESTHESIA AND INTENSIVE CARE, 1988, 16 (03) :265-271
[6]  
KATICH M, 1988, J INFECT DIS, V5, P971
[7]   CANNULA THROMBOPHLEBITIS - A STUDY IN VOLUNTEERS COMPARING POLYTETRAFLUOROETHYLENE, POLYURETHANE, AND POLYAMIDE-ETHER-ELASTOMER CANNULAE [J].
LARSSON, N ;
STENBERG, K ;
LINDER, LE ;
CURELARU, I .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1989, 33 (03) :223-231
[8]  
Lawson M, 1986, NITA, V9, P40
[9]   CONTAMINATION REDUCTION DURING CENTRAL VENOUS CATHETERIZATION [J].
LEVY, JH ;
NAGLE, DM ;
CURLING, PE ;
WALLER, JL ;
KOPEL, M ;
TOBIA, V .
CRITICAL CARE MEDICINE, 1988, 16 (02) :165-167
[10]   INFUSION THROMBOPHLEBITIS [J].
LEWIS, GBH ;
HECKER, JF .
BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (02) :220-233