METHYLTETRAHYDROPHTHALIC ANHYDRIDE IN AIR - SAMPLING AND ANALYSIS

被引:10
作者
WELINDER, H
GUSTAVSSON, C
机构
[1] Department of Occupational and Environmental Medicine, University Hospital
关键词
D O I
10.1093/annhyg/36.2.189
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Methyltetrahydrophthalic anhydride (MTHPA), an organic anhydride, is a sensitizing agent even at low air concentrations: no methods for its sampling and analysis have previously been reported. This paper outlines the use of Amberlite XAD-2 for sampling MTHPA vapour in air, followed by analysis using gas chromatography with flame ionization detection. The level of detection corresponds to a concentration in air of 10-mu-g m-3 for a 20 1. sampling volume. Up to 200 1. air has been sampled, at a sampling rate of 1 1. min-1, without detectable losses. The adsorption efficiency and the stability of the anhydride in the XAD-2 tubes were not influenced by a relative air humidity (RH) of 40%, but at RH 80% there was a loss of 18% at 50 1. air-sample volume. Results from sampling in XAD-2 tubes were 8% lower than those from parallel sampling in midget bubblers containing 10 ml 0.01 M sodium hydroxide.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 12 条
[1]   INFLUENCE OF AIR HUMIDITY ON SAMPLING EFFICIENCY OF SOME SOLID ADSORBENTS USED FOR SAMPLING ORGANICS FROM WORK-ROOM AIR [J].
ANDERSSON, K ;
LEVIN, JO ;
LINDAHL, R ;
NILSSON, CA .
CHEMOSPHERE, 1984, 13 (03) :437-444
[2]   DETERMINATION OF PHTHALIC-ANHYDRIDE IN WORKPLACE AIR USING REVERSE PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GEYER, R ;
SAUNDERS, GA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (10) :2281-2290
[3]   DETERMINATION OF HEXAHYDROPHTHALIC ANHYDRIDE IN AIR USING GAS-CHROMATOGRAPHY [J].
JONSSON, B ;
WELINDER, H ;
SKARPING, G .
JOURNAL OF CHROMATOGRAPHY, 1991, 558 (01) :247-256
[4]  
NEILSEN J, 1988, J ALLERGY CLIN IMMUN, V82, P126
[5]   ALLERGIC AIRWAY DISEASE CAUSED BY METHYL TETRAHYDROPHTHALIC ANHYDRIDE IN EPOXY-RESIN [J].
NIELSEN, J ;
WELINDER, H ;
SKERFVING, S .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1989, 15 (02) :154-155
[6]   AIR SAMPLING AND ANALYSIS OF TRIMELLITIC ANHYDRIDE [J].
PALASSIS, J ;
POSNER, JC ;
SLICK, E ;
SCHULTE, K .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1981, 42 (11) :785-789
[8]  
VENABLES KM, 1989, BRIT J IND MED, V46, P222
[9]   SPECIFIC ANTIBODIES TO METHYLTETRAHYDROPHTHALIC ANHYDRIDE IN EXPOSED WORKERS [J].
WELINDER, H ;
NIELSEN, J ;
GUSTAVSSON, C ;
BENSRYD, I ;
SKERFVING, S .
CLINICAL AND EXPERIMENTAL ALLERGY, 1990, 20 (06) :639-645
[10]  
1981, OSHA METHOD, V25