TRANSPORT EFFECTS WITH DRIBBLE AND JET ULTRASONIC NEBULIZERS

被引:45
作者
TARR, MA [1 ]
ZHU, GX [1 ]
BROWNER, RF [1 ]
机构
[1] GEORGIA INST TECHNOL,SCH CHEM & BIOCHEM,ATLANTA,GA 30332
关键词
INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; ULTRASONIC NEBULIZER; ANALYTE TRANSPORT; SOLVENT TRANSPORT;
D O I
10.1039/ja9920700813
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ultrasonic nebulizers improve analyte transport compared with pneumatic types, but require partial or total solvent removal. Aerosol desolvation, using a heated chamber followed by a condenser, not only reduces the solvent loading in the plasma, but also increases the analyte transport relative to transport without desolvation. The influence on emission signals of the interaction of each component in the sample introduction system in terms of analyte and solvent transport losses are reported. Significant analyte losses in the spray chamber and condenser are observed and various approaches to improving analyte transport are presented. Two configurations of sample injection into the ultrasonic nebulizer. the dribble and jet type, are compared, with the jet type showing greater repeatability and improved peak shape for flow injection measurements.
引用
收藏
页码:813 / 817
页数:5
相关论文
共 9 条
[1]   ULTRASONIC NEBULIZATION OF LIQUID SAMPLES FOR ANALYTICAL INDUCTIVELY COUPLED PLASMA-ATOMIC SPECTROSCOPY - AN UPDATE [J].
FASSEL, VA ;
BEAR, BR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (10) :1089-1113
[2]   ANALYTICAL IMPROVEMENT OF PNEUMATIC NEBULIZATION IN ICP-MS BY DESOLVATION [J].
JAKUBOWSKI, N ;
FELDMANN, I ;
STUEWER, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (01) :107-118
[3]   ULTRASONIC ATOMIZATION OF LIQUIDS [J].
LANG, RJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1962, 34 (01) :6-&
[4]   ARGON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH THERMOSPRAY, ULTRASONIC, AND PNEUMATIC NEBULIZATION [J].
MONTASER, A ;
TAN, H ;
ISHII, I ;
NAM, SH ;
CAI, MX .
ANALYTICAL CHEMISTRY, 1991, 63 (22) :2660-2665
[5]   MULTIELEMENT DETECTION LIMITS AND SAMPLE NEBULIZATION EFFICIENCIES OF AN IMPROVED ULTRASONIC NEBULIZER AND A CONVENTIONAL PNEUMATIC NEBULIZER IN INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY [J].
OLSON, KW ;
HAAS, WJ ;
FASSEL, VA .
ANALYTICAL CHEMISTRY, 1977, 49 (04) :632-637
[6]   STUDIES OF ULTRASONIC NEBULIZER PARAMETERS IN SEARCH OF A SIMPLE, RELIABLE SYSTEM [J].
PETRUCCI, GA ;
VANLOON, JC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (08) :959-968
[7]   FUNDAMENTAL AEROSOL STUDIES WITH AN ULTRASONIC NEBULIZER [J].
TARR, MA ;
ZHU, GX ;
BROWNER, RF .
APPLIED SPECTROSCOPY, 1991, 45 (09) :1424-1432
[8]   SENSITIVITIES OF INDUCTIVELY COUPLED PLASMA OPTICAL-EMISSION SPECTROMETRY FOR DRY AND WET AEROSOLS [J].
WEBER, AP ;
KEIL, R ;
TOBLER, L ;
BALTENSPERGER, U .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :672-677
[9]  
ZHU G, 1989, 1989 PITTSB C AN CHE