MEASUREMENT OF PHASE ERROR DISTRIBUTIONS IN SILICA-BASED ARRAYED-WAVE-GUIDE GRATING MULTIPLEXERS BY USING FOURIER-TRANSFORM SPECTROSCOPY

被引:44
作者
TAKADA, K
INOUE, Y
YAMADA, H
HORIGUCHI, M
机构
[1] NTT Optoelectronics Laboratories Tokai, Ibaraki-Ken, 319-11, Naka-Gun
关键词
GRATING DEMULTIPLEXERS; FOURIER TRANSFORMS; SPECTROSCOPY;
D O I
10.1049/el:19941113
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The phase errors caused by deviations in the designed lengths of the optical paths in silica-based arrayed-waveguide grating (AWG) multiplexers were measured using Fourier transform spectroscopy. The measurement accuracy was +/- 1 degrees. The phase errors in an AWG multiplexer with a channel spacing of 10GHz and a channel crosstalk of -15dB were randomly distributed between -122 and 90 degrees.