DYSTROPHIC CALCIFICATION OF SILICONE SCLERAL BUCKLING IMPLANT MATERIALS

被引:27
作者
BROCKHURST, RJ
WARD, RC
LOU, P
ORMEROD, D
ALBERT, D
机构
[1] WISCONSIN HOSP & CLIN,DEPT OPHTHALMOL,MADISON,WI
[2] HARVARD UNIV,SCH MED,DEPT OPHTHALMOL,BOSTON,MA 02115
[3] KRESAGE EYE INST,DEPT OPHTHALMOL,DETROIT,MI
关键词
D O I
10.1016/S0002-9394(14)74457-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
In six patients, removal of solid silicone scleral buckling implant materials that had been in place between eight and 21 years disclosed gray-white deposits firmly adherent to the silicone. Four of the six patients had culture-proven infections, whereas two had no evidence of infection and had negative cultures. One of these two patients, however, had intermittent pain, which was the indication for removal of the implant. Analysis of the deposits disclosed that they were calcium phosphate. The exact mechanism responsible for the calcification on the silicone material is unknown. Dystrophic calcification can occur without infection in injured tissue wherein extracellular deposits of devitalized cells, blood cells, and lipids may act as a nidus for calcification. In the presence of infection, bacteria may serve as such a nidus. Additionally, it is possible that biofilm produced by the bacteria had a role in the deposition of calcium phosphate, as well as in its firm adhesion to the silicone materials. We considered the possibility of similar deposits developing on intraocular silicone lenses.
引用
收藏
页码:524 / 529
页数:6
相关论文
共 21 条
[1]  
ANDERSON HC, 1988, RHEUM DIS CLIN N AM, V14, P303
[2]  
BARTLEY GB, 1985, RETINA, V1, P42
[3]  
Briggs D., 1990, PRACTICAL SURFACE AN, V2nd, P1
[4]  
CARMEN R, 1968, Journal of Biomedical Materials Research, V2, P457, DOI 10.1002/jbm.820020406
[5]   LIPID ABSORPTION BY SILICONE-RUBBER HEART VALVE POPPETS IN-VIVO AND IN-VITRO RESULTS [J].
CARMEN, R ;
MUTHA, SC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1972, 6 (05) :327-&
[6]  
CHEVRY HS, 1988, RHEUM DIS CLIN N AM, V14, P365
[7]   BACTERIAL BIOFILMS IN NATURE AND DISEASE [J].
COSTERTON, JW ;
CHENG, KJ ;
GEESEY, GG ;
LADD, TI ;
NICKEL, JC ;
DASGUPTA, M ;
MARRIE, TJ .
ANNUAL REVIEW OF MICROBIOLOGY, 1987, 41 :435-464
[8]   SPONTANEOUS ALTERATIONS IN UNUSED SILICON BUCKLING MATERIAL [J].
DODEN, W ;
SCHNAUDIGEL, OE .
DOCUMENTA OPHTHALMOLOGICA, 1981, 50 (02) :249-253
[9]  
Dunn J.M., 1985, CARDIOL CLIN, V3, P385, DOI [10.1016/s0733-8651(18)30664-7, DOI 10.1016/S0733-8651(18)30664-7]
[10]  
HOLLAND SP, 1991, OPHTHALMOLOGY, V98, P933