STUDIES IN CAPILLARY ZONE ELECTROPHORESIS WITH A POSTCOLUMN MULTIPLE CAPILLARY DEVICE FOR FRACTION COLLECTION AND STEPWISE INCREASE IN ELECTROOSMOTIC FLOW DURING ANALYSIS

被引:24
作者
NASHABEH, W [1 ]
SMITH, JT [1 ]
ELRASSI, Z [1 ]
机构
[1] OKLAHOMA STATE UNIV,DEPT CHEM,STILLWATER,OK 74078
关键词
D O I
10.1002/elps.1150140166
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new approach involving the stepwise increase in electroosmotic flow during analysis in capillary zone electrophoresis is introduced and evaluated in the rapid separations of proteins and peptides. The stepwise increase in electroosmotic flow is based on the principle of coupled capillaries in series having different flow characteristics, a concept that was introduced recently by our laboratory. To produce stepwise changes in electroosmotic flow during analysis, a post-column multiple capillary device, which allowed the switching between several coupled capillary systems, was designed and constructed in-house. The utility of the multiple capillary device was also demonstrated and extended to fraction collection of separated analytes in short capillary segments, The fraction collection in capillaries facilitated the quantitative transfer of the collected fractions to high performance liquid chromatography (HPLC) for further analysis or to mass spectrometry (MS) for structural determination. The off-line combination of capillary zone electrophoresis with HPLC or MS utilized commercial instruments without the need of expensive interfacing designs.
引用
收藏
页码:407 / 416
页数:10
相关论文
共 26 条
[1]  
BOCEK P, 1989, J CHROMATOGR, V470, P309
[2]   NEW OPTION IN CAPILLARY ZONE ELECTROPHORESIS - USE OF A TRANSIENT IONIC MATRIX (DYNAMIC PULSE) [J].
BOCEK, P ;
DEML, M ;
POSPICHAL, J .
JOURNAL OF CHROMATOGRAPHY, 1990, 500 :673-680
[3]   CONTINUOUS-FLOW SAMPLE PROBE FOR FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
CAPRIOLI, RM ;
FAN, T ;
COTTRELL, JS .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :2949-2954
[4]   RAPID SEPARATION AND PURIFICATION OF OLIGONUCLEOTIDES BY HIGH-PERFORMANCE CAPILLARY GEL-ELECTROPHORESIS [J].
COHEN, AS ;
NAJARIAN, DR ;
PAULUS, A ;
GUTTMAN, A ;
SMITH, JA ;
KARGER, BL .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (24) :9660-9663
[5]   PREPARATIVE CAPILLARY ELECTROPHORESIS BASED ON ADSORPTION OF THE SOLUTES (PROTEINS) ONTO A MOVING BLOTTING MEMBRANE AS THEY MIGRATE OUT OF THE CAPILLARY [J].
ERIKSSON, KO ;
PALM, A ;
HJERTEN, S .
ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) :211-215
[6]   APPLICABILITY OF DYNAMIC CHANGE OF PH IN THE CAPILLARY ZONE ELECTROPHORESIS OF PROTEINS [J].
FORET, F ;
FANALI, S ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :219-222
[7]  
FUJIMOTO C, 1991, HRC-J HIGH RES CHROM, V14, P178
[8]  
FUJIMOTO C, 1992, HRC-J HIGH RES CHROM, V15, P201
[9]   THE USE OF A CONCENTRATION STEP TO COLLECT URINARY COMPONENTS SEPARATED BY CAPILLARY ELECTROPHORESIS AND FURTHER CHARACTERIZATION OF COLLECTED ANALYTES BY MASS-SPECTROMETRY [J].
GUZMAN, NA ;
TREBILCOCK, MA ;
ADVIS, JP .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (05) :997-1015
[10]   CAPILLARY ELECTROPHORESIS FOR THE ANALYTICAL SEPARATION AND SEMIPREPARATIVE COLLECTION OF MONOCLONAL-ANTIBODIES [J].
GUZMAN, NA ;
TREBILCOCK, MA ;
ADVIS, JP .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :247-255