A computer-controlled conformal radiotherapy system .3. Graphical simulation and monitoring of treatment delivery

被引:27
作者
Kessler, ML
McShan, DL
Fraass, BA
机构
[1] Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 05期
关键词
conformal therapy; computer-controlled; treatment delivery; collision detection; simulation; verification;
D O I
10.1016/0360-3016(95)02045-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Safe and efficient delivery of radiotherapy using computer-controlled machines requires new procedures to design and verify the actual delivery of these treatments. Graphical simulation and monitoring techniques for treatment delivery have been developed for this purpose. Methods and Materials: A graphics-based simulator of the treatment machine and a set of procedures for creating and manipulating treatment delivery scripts. are used to simulate machine motion, detect collisions, and monitor machine positions during treatment. The treatment delivery simulator is composed of four components: a three-dimensional dynamic model of the treatment machine; a motion simulation and collision detection algorithm, user-interface widgets that mimic the treatment machine's control and readout devices; and an icon-based interface far creating and manipulating treatment delivery scripts. These components are used in a stand-alone fashion for interactive treatment delivery planning and integrated with a machine control system for treatment implementation and monitoring. Results: A graphics-based treatment delivery simulator and a set of procedures for planning and monitoring computer-controlled treatment delivery have been developed and implemented as part of a comprehensive computer-controlled conformal radiotherapy system, To date, these techniques have been used to design and help monitor computer-controlled treatments on a radiotherapy machine for more than 200 patients. Examples using these techniques for treatment delivery planning and on-line monitoring of machine motions during therapy are described. Conclusion: A system that provides interactive graphics-based tools for defining the sequence of machine motions, simulating treatment delivery including collision detection, and presenting the therapists with continual visual feedback from the treatment machine has been successfully implemented for routine clinical use as part of an overall system for computer-controlled conformal radiotherapy treatment, and is considered a necessary part of the routine treatment methodology.
引用
收藏
页码:1173 / 1180
页数:8
相关论文
共 15 条
[1]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[2]  
BRAHME A, 1983, Radiotherapy and Oncology, V1, P65, DOI 10.1016/S0167-8140(83)80008-5
[3]  
COMER DE, 1993, INTERNETWORKING TCP, V3
[4]  
CROCKFORD DJ, 1994, 11TH P INT C US COMP, P350
[5]  
FOLEY JD, 1992, COMPUTER GRAPHICS
[6]   A computer-controlled conformal radiotherapy system .1. Overview [J].
Fraass, BA ;
McShan, DL ;
Kessler, ML ;
Matrone, GM ;
Lewis, JD ;
Weaver, TA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1139-1157
[7]   A computer-controlled conformal radiotherapy system .4. Electronic chart [J].
Fraass, BA ;
McShan, DL ;
Matrone, GM ;
Weaver, TA ;
Lewis, JD ;
Kessler, ML .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1181-1194
[8]   CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM [J].
GALVIN, JM ;
SMITH, AR ;
LALLY, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :181-192
[9]   COLLISION-AVOIDANCE IN COMPUTER-OPTIMIZED TREATMENT PLANNING [J].
HUMM, JL .
MEDICAL PHYSICS, 1994, 21 (07) :1053-1064
[10]   PHOTON-BEAM CHARACTERISTICS ON THE MM50 RACETRACK MICROTRON AND A NEW APPROACH FOR BEAM QUALITY DETERMINATION [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1993, 20 (01) :143-149